Note: Ingredients listed on restricted chemical lists
EC/CAS
7664-41-7
Name of the chemical
Ammonia
Concentration
N/A
EC/CAS
7727-37-9
Name of the chemical
Nitrogen N2
Concentration
N/A
General Information
Revision date
2018-05-29
Product name
Ammonia 0.1000% to 4.0% in Air
Chemical name
Gas Mixture
CAS No.
Not
1.2.1 Relevant identified uses
Calibration of analyitical instrumentation
Manufacturer Name
NorLab a division of Norco
Icons in SDS
Company Information
company name
NorLab a division of Norco
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H280, H315, H319, H332
Hazard statements
Code
Statements
H280
Contains gas under pressure; may explode if heated
H315
Causes skin irritation
H319
Causes serious eye irritation
H332
Harmful if inhaled
Section 2
OSHA HCS Classification
Physical, Gases Under Pressure, Compressed Gas Health, Skin corrosion/irritation, 2 Health, Acute toxicity, 4 Inhalation Health, Serious Eye Damage/Eye Irritation, 2 A
Signal word
WARNING
Hazard statements
H280 - Contains gas under pressure; may explode if heated H315 - Causes skin irritation H332 - Harmful if inhaled H319 - Causes serious eye irritation CGA-HG24 - SUPPORTS COMBUSTION.
Precautionary statements
P202 - Do not handle until all safety precautions have been read and understood. P260 - Do not breathe dust/fume/gas/mist/vapors/spray. P262 - Do not get in eyes, on skin, or on clothing. SDS Page 2 of 11 P280 - Wear protective gloves/protective clothing/eye protection/face protection. P304+340 - IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. P305+351+338 - IF IN EYES: Rinse continuously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing. P312 - Call a POISON CENTER or doctor/physician if you feel unwell. P403+233 - Store in a well ventilated place. Keep container tightly closed. P410+412 - Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F CGA-PG05 - Use a back flow preventive device in the piping. CGA-PG06 - Close valve after each use and when empty. CGA-PG10 - Use only with equipment rated for cylinder pressure. CGA-PG12 - Do not open valve until connected to equipment prepared for use.
Principle Routes of Exposure
Inhalation; Skin; Eyes; Target Organs: Eyes; Respiratory system; Skin; Inhalation: Effects depend or concentration inhaled. Low concentrations may cause irritation. Higher concentrations may cause more severe irritation with possible corrosion of the upper respiratory system and mucous membranes, chemical pneumonitis and pulmonary edema (lung swelling and fluid retention). Symptoms are dependent upon concentration inhaled and may include burning sensation, coughing, wheezing, shortness of breath, headache, nausea with eventual collapse and death. Skin Contact: May cause irritation, redness, and dermatitis. Contact with rapidly expanding gas near the point of release may cause frostbite with redness, skin color change to gray or white, and blistering. Eye Contact: May cause irritation with associated redness, swelling, and tears. Ammonia can cause eye damage with corneal burns if not rinsed promptly. Contact with rapidly expanding gas near the point of release may cause frostbite. Ingestion: Not anticipated. Product is a gas at normal conditions. NFPA: Health = 2, Fire = 0, Reactivity = 0, Specific Hazard = n/a HMIS III: Health = 2, Fire = 0, Physical Hazard = 3 HMIS PPE: G - Safety Glasses, Gloves, Vapor Respirator 2 0 2 0 3 G