1,3-butadiene

NIPPON GASES ESPAÑA, S.L.U

Revision date : 2021-07-23

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS02 GHS04 GHS08
Health risk rating 5
Safety risk rating 4
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

106-99-0

Name of the chemical

1,3-Butadien

Concentration

N/A

EC/CAS

203-450-8

Name of the chemical

1,3-Butadien

Concentration

N/A

General Information

Revision date

2021-07-23

Product name

1,3-butadiene

Chemical name

1,3 BUTADIENO

CAS No.

106-99-0

1.2.1 Relevant identified uses

See the list of identified uses and exposure scenarios in the annex of the safety data sheet Perform risk assessment prior to use

Icons in SDS

Company Information

company name

NIPPON GASES ESPAÑA, S.L.U

e-mail address of the competent person responsible for the Safety Data Sheet

info.spain@nippongases.com

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H220, H280, H340, H350

Hazard statements

Code

Statements

H220

Extremely flammable gas

Section 2

Physical hazards

Flammable gases, Category 1A H220 Gases under pressure : Liquefied gas H280

Health hazards

Germ cell mutagenicity, Category 1B H340 Carcinogenicity, Category 1A H350

2.2 Label elements

Labelling according to Regulation (EC) No. 1272/2008 [CLP]

Hazard pictograms

GHS02 GHS04 GHS08

Signal word

Danger

Hazard statements

H220 - Extremely flammable gas. H280 - Contains gas under pressure; may explode if heated. H340 - May cause genetic defects. H350 - May cause cancer.

Prevention

P202 - Do not handle until all safety precautions have been read and understood. P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

Response

P308+P313 - IF exposed or concerned: Get medical advice/attention. P377 - Leaking gas fire: Do not extinguish, unless leak can be stopped safely. P381 - In case of leakage, eliminate all ignition sources.

Storage

P403 - Store in a well-ventilated place.

Additional information

Restricted to professional users.

2.3 Other hazards

Contact with liquid may cause cold burns/frostbite.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.