Note: Ingredients listed on restricted chemical lists
EC/CAS
7440-44-0
Name of the chemical
Carbon black
Concentration
≥60-≤75
EC/CAS
1344-28-1
Name of the chemical
aluminium oxide
Concentration
≥10-≤30
EC/CAS
7789-75-5
Name of the chemical
Calcium fluoride
Concentration
≤3
EC/CAS
14808-60-7
Name of the chemical
Silica, crystalline
Concentration
≤0.1
General Information
Revision date
2023-10-27
Product name
Carbon anode fines (Rodding 090 DC crusher)
1.2.1 Relevant identified uses
Fuel and additive in steel and cement industry
supplier name
New Zealand Aluminium Smelters Ltd
Emergency telephone
+64 (0) 9 929 1483
Icons in SDS
Company Information
company name
New Zealand Aluminium Smelters Ltd
e-mail address of the competent person responsible for the Safety Data Sheet
rta.msds@riotinto.com
GHS Information
Signal word
Danger
Section 2
SECTION 2: Hazards identification
HSNO Classifications
ACUTE TOXICITY (inhalation) - Category 4 SPECIFIC TARGET ORGAN TOXICITY - REPEATED EXPOSURE - Category 1 LONG-TERM (CHRONIC) AQUATIC HAZARD - Category 3 This material is classified as hazardous according to criteria in the Hazardous Substances (Hazard Classification) Notice 2020. This material is not classified as DANGEROUS GOODS according to criteria in New Zealand Standard 5433:2012 Transport of Dangerous Goods on Land.
Signal word
Danger
Hazard statements
Harmful if inhaled. Causes damage to organs through prolonged or repeated exposure. Harmful to aquatic life with long lasting effects.
Prevention
Use only outdoors or in a well-ventilated area. Avoid release to the environment. Do not breathe dust or mist. Do not eat, drink or smoke when using this product. Wash thoroughly after handling.
Response
Get medical advice/attention if you feel unwell. IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER or doctor if you feel unwell.
Storage
Not applicable.
Disposal
Dispose of contents and container in accordance with all local, regional, national and international regulations.
Other hazards which do not result in classification
Depending on the type of handling and use (e.g. grinding, drying), airborne respirable crystalline silica (quartz - cristobalite) may be generated. Prolonged and/ or massive inhalation of respirable crystalline silica dust may cause lung fibrosis, commonly referred to as silicosis. Principal symptoms of silicosis are cough and breathlessness. Occupational exposure to respirable crystalline silica dust should be monitored and controlled. Some carbon dust materials are known to be combustible. The material describe in this SDS have been tested and the dust did not demonstrate any explosive behavior. Nevertheless, as with all finely divided materials, some handling precautions are recommended in section 7 and site/equipment/task specific risk assessment are recommended.