General Information
Revision date
2011-09-08
Product name
This Standard Reference Material (SRM) is intended for use as a primary for critical evaluation of daily working standards used in spectrophotometry and for use as an accuracy check of the photometric scale of spectrophotometers. One unit of SRM 931g consists of twelve 10 mL sealed glass ampoules of solution. Three
Substance name
Dilute Perchloric Acid solution
Product Synonyms
Perchloric Acid (dioxonium perchlorate; perchloric acid solution; perchloric acid; HClO4)
CAS No.
7601-90-3
Emergency telephone
ChemTrec
Icons in SDS
Company Information
company name
National Institute of Standards and Technology
e-mail address of the competent person responsible for the Safety Data Sheet
SRMMSDS@nist.gov
Section 2
NFPA Ratings
Scale 0–4) Health = 3 Fire = 0 Reactivity = 0 NOTE: The health and physical hazard information provided in this MSDS are for perchloric acid. No physical or chemical data are listed for this dilute perchloric acid solution. The actual effects of the solution may differ from the individual components.
Health hazards
Perchloric acid is corrosive and can cause severe or fatal burns if inhaled, swallowed, or absorbed through the skin. Severity of the damage depends on the concentration and duration of exposure.
Physical hazards
There are no known physical hazards associated with this material
Potential health effects
Inhalation: Inhalation of perchloric acid can damage the mucous membranes and upper respiratory tract. Short term exposure may cause irritation and inflammation of the upper respiratory tract, coughing, choking, sore throat, shortness of breath, headache, dizziness, and nausea. Long term exposure to acid fumes may cause damage to teeth, bronchial irritation, chronic cough, bronchial pneumonia, and gastrointestinal disturbances. Skin Contact: Perchloric acid can cause severe skin burns. Effects may be delayed. Severity of the damage depends on the concentration and duration of exposure. Eye Contact: Perchloric acid can cause severe eye burns, permanent eye damage, or blindness. Ingestion: Ingestion of this material is unlikely under normal conditions of use. If ingested, perchloric acid can cause severe burns and damage to the gastrointestinal tract.
Medical Conditions Generally Aggravated by Exposure
This material may aggravate pre-existing eye disorders, respiratory disorders, skin disorders, and allergies. Listed as a Carcinogen/Potential Carcinogen: Component: Perchloric Acid Yes No In the National Toxicology Program (NTP) Report on Carcinogens X In the International Agency for Research on Cancer (IARC) Monographs X By the Occupational Safety and Health Administration (OSHA) X 3. COMPOSITION AND INFORMATION ON HAZARDOUS INGREDIENTS NOTE: SRM 931g contains nine 10 mL solutions each containing containing trace amounts of cobalt and nickel. The concentration of these elements is below the reportable limit: hazardous components (1 %); carcinogens (0.1 %), required by OSHA, 29 CFR 1910.1200 (g) (2) (i) (C) (1), for MSDS information. The physical and chemical data provided are for perchloric acid. The actual behavior of the solution may differ from the pure component. Component(a) CAS Number EC Number Nominal Mass Concentration (EINECS) (%) Perchloric Acid 7601-90-3 231-512-4 1.0 (a)This material has not been tested as a whole. Hazardous components 1 % or greater; carcinogens 0.1 % or greater are listed in compliance with OSHA 29 CFR 1910.1200(g)(2)(i)(C)(1). Components: Perchloric Acid (7 % Solution) EC Classification: Xi, EC Risk (R No.): R36/38 EC Safety (S No.): 23, 26, 36, 45 EC Classification Risk/Safety Phrases: Refer to Section 15, “Regulatory Information”. NOTE: The EC classifications for Perchloric acid vary based on the concentration of the acid in the solution. The information provided above is for a 1.0 % perchloric acid solution, the concentration in this SRM.