Note: Ingredients listed on restricted chemical lists
EC/CAS
7440-02-0
Name of the chemical
Nickel
Concentration
N/A
EC/CAS
7440-47-3
Name of the chemical
Chromium‡
Concentration
N/A
General Information
Revision date
2017-11-21
Product name
Stainless Steel for EPMA
Substance name
Stainless Steel for EPMA
1.2.1 Relevant identified uses
This certified reference material (CRM) is intended to use in of the Chemical calibrating concentration of elements during the electron probe micro
supplier name
National Institute of Advanced Industrial Science and Technology
Emergency telephone
Prepared on : August 29, 2007
Icons in SDS
Company Information
company name
National Institute of Advanced Industrial Science and Technology (AIST)
GHS Information
Signal word
Danger
Section 2
2.1 Classification of the substance or mixture
Respiratory organ
Hazard categories
1 sensitization Skin Sensitization 1 Germ cell mutagenicity 2 Carcinogenicity 2
Signal word
Danger Hazard and May cause an allergic skin reaction. toxicity Suspect of causing genetic defects. May cause allergy, asthma or breathing difficulty if inhaled. May cause cancer.
2.3 Other hazards
Powder of iron-chromium alloy may cause eye irritation.
Hazard statements
May cause metal fume fever. May cause respiratory tract irritation. Precautionary Do not breathe dust, mist, vapors, etc. Avoid release to the environment. Do not eat, drink or smoke when using this product. Use appropriate personal protective equipment. Wash personal protective equipment thoroughly after use. Wash hands thoroughly after handling. Use protective globes. When dust is generated, seal the source, and wear respiratory protection equipment. [Action] If inhaled: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical advice/attention if you feel unwell. If swallowed: Rinse mouth. Do not induce vomiting. Immediately get medical advice/attention. If in eyes: Rinse with running water for several minutes. Get medical advice/attention. If on skin: Remove/Take off all contaminated clothing and adhered materials. Rinse skin with running water and soap. Immediately get medical advice/attention if you feel unwell. If exposed: Get medical advice/attention.
Storage
This CRM should be kept in locked and keyed. Keep out direct sun light and high relative humidity. Store this CRM in a clean place at normal room temperature.
Disposal
Dispose of this reference material in accordance with applicable legislation and local government ordinance. Entrust disposal of this reference material to a professional waste disposal company licensed by prefectural governor. The other hazards than the above do not result in classification or are not classifiable.