Note: Ingredients listed on restricted chemical lists
EC/CAS
110-82-7
Name of the chemical
Cyclohexane
Concentration
N/A
General Information
Revision date
2017-11-13
Product name
Cyclohexane for Thermal Analysis
Substance name
Cyclohexane for Thermal Analysis
CAS No.
110-82-7
1.2.1 Relevant identified uses
This CRM is intended for use in the calibration, quality control and of the Chemical and validation of thermal analyzers such as differential scanning
1.2.2. Uses advised against
calorimeters and differential thermal analyzers Do not use this reference material for other purposes than testing/research
supplier name
National Institute of Advanced Industrial Science and Technology
Emergency telephone
Prepared on : July 13, 2009
Icons in SDS
Company Information
company name
National Institute of Advanced Industrial Science and Technology (AIST)
GHS Information
Signal word
Danger
Section 2
2.1 Classification of the substance or mixture
Flammable liquid Class 2 Skin corrosivity/irritant Class 2 Severe eye damage/eye Class 2A irritant Reproductive toxicity Class 2 Particular target Class 2 (Blood system) organ/systemic toxicity Class 3 (Respiratory tract irritant, (Single exposure) anesthetic action)
Aspiration hazard
Class 2 Water environment toxicity Class 1 (Acute)
Signal word
Danger Hazard and toxicity: Highly flammable liquid and vapor. Skin irritation. Severe eye irritation. May have adverse effects on reproductive function and embryo. May damage organs (blood system, respiratory tract irritation, anesthetic action). May irritate respiratory organ. May cause drowsiness or dizziness. May be harmful by swallowing or entering respiratory tract. Severely toxic to aquatic organisms. Precautionary [Preventive measures]
Hazard statements
Obtain an instruction manual, read and understand the safety precautions fully before handling. Use protective eyeglasses, protective mask .and protective gloves. Handle the material in outdoor or in well ventilated area. Keep away from heat, sparks, open flame, high temperature matters. No smoking. Take preventive measures against electrostatic discharge. Wash hands well after handling. Avoid inhaling mist, vapor. Avoid discharging to the environment. Keep the container airtight.
Response
If swallowed : Seek medical advice immediately. If in eyes : Rinse carefully with water for several minutes. If contact lenses are inserted, take them out if possible and continue to rinse. If eye irritation persists, seek medical advice. If feeling unwell : Seek medical advice. If inhaled : Move to a fresh air, take a comfortable posture to ease breathing and rest. If on skin : Take off all contaminated clothing immediately. Wash with soap and a large amount of water (running water/shower). In case of skin irritation, seek medical advice. Exposure or possible exposure: Seek medical advice.
Storage
Keep the container airtight and store in a cool and well ventilated place. Lock up the container in a safety cabinet.
Disposal
This material or its container should be outsourced to a professional industrial waste disposal contractor licensed by relevant authorities (national, local). Hazardous and toxic properties not specified in the above are neither the object of the classification nor classifiable.