Note: Ingredients listed on restricted chemical lists
EC/CAS
265-150-3/64742-48-9
Name of the chemical
Naphtha (petroleum), hydrotreated heavy
Concentration
10 - 30 %
EC/CAS
201-607-5/85-44-9
Name of the chemical
Phthalic anhydride
Concentration
N/A
General Information
Revision date
2016-10-19
Product name
SOLO GOYA Goldleaf primer
supplier name
Mrs. Treiber
Emergency telephone
+49 (0) 9545 925-0
Icons in SDS
Company Information
company name
Mrs. Treiber
e-mail address of the competent person responsible for the Safety Data Sheet
info@c-kreul.de, b.treiber@c-kreul.de
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H226, H336, H372, H412
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
Section 2
CLP CLASSIFICATION
Flam. Liq. 3 H226; STOT SE 3 H336; STOT RE 1 H372; Aquatic Chron. 3 H412 Labelling according to Regulation (EC) 1272/2008 Hazard pictogram and signal word of the product Danger
Hazardous Ingredients
Hydrocarbons, C9-C11, < 2% aromatics CAS 64742-48-9, solvent naphtha (petroleum), medium aliph. CAS 84742-88-7.
Hazard statements
H226 Flammable liquid and vapour. H336 May cause drowsiness or dizziness. H372 Causes damage to organs through prolonged or repeated exposure. H412 Harmful to aquatic life with long lasting effects. European hazard statements EUH066 Repeated exposure may cause skin dryness or cracking. EUH208 Contains phthalic anhydride. May produce an allergic reaction.
Precautionary statements
P101 If medical advice is needed, have product container or label at hand. P102 Keep out of reach of children. P243 Take precautionary measures against static discharge. P260 Do not breathe vapours/spray. P270 Do not eat, drink or smoke when using this product. P271 Use only outdoors or in a well-ventilated area. P370+P378 In case of fire: Use sand, carbon dioxide or powdered extinguishing agent for extinction. P405 Store locked up. P501 Dispose of contents/container to hazardous or special waste collection point.
2.3 Other hazards
Flammable liquid and vapour. Vapours may form explosive mixtures with air. This material is combustible and can be ignited by heat, sparks, flames, or other sources of ignition (e.g. static electricity, pilot lights, or mechanical / electrical equipment). Take precautionary measures against static discharges.
Results of PBT and vPvB assessment
Not applicable