Note: Ingredients listed on restricted chemical lists
EC/CAS
111-76-2
Name of the chemical
Ethylene glycol monobutyl ether (EGBE)
Concentration
N/A
EC/CAS
68476-85-7
Name of the chemical
Petroleum gases, liquefied
Concentration
N/A
General Information
Revision date
2019-06-08
Product name
AEROSOLS
Product Synonyms
G190719 (19oz/539g)
1.2.1 Relevant identified uses
Application is by spray atomisation from a hand held aerosol pack
Emergency telephone
61 2 9737 9422 (For General Information Monday to Friday 8 30am to 5 pm
Icons in SDS
Company Information
company name
Motor Active
e-mail address of the competent person responsible for the Safety Data Sheet
andrew.spira@motoractive.com.au
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H222, H370
Hazard statements
Code
Statements
H222
Extremely flammable aerosol
Section 2
2.1 Classification of the substance or mixture
HAZARDOUS CHEMICAL. DANGEROUS GOODS. According to the WHS Regulations and the ADG Code. CHEMWATCH HAZARD RATINGS Min Max Flammability 1 Toxicity 0 0 = Minimum Body Contact 1 1 = Low 2 = Moderate Reactivity 1 3 = High Chronic 0 4 = Extreme Poisons Schedule
Classifications
1] Aerosols Category 1, Specific target organ toxicity - single exposure Category 1 Legend: 1. Classified by Chemwatch; 2. Classification drawn from HCIS; 3. Classification drawn from Regulation (EU) No 1272/2008 - Annex VI
Signal word
DANGER
Hazard statements
H222 Extremely flammable aerosol. H370 Causes damage to organs. AUH044 Risk of explosion if heated under confinement.
Prevention
P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking. P211 Do not spray on an open flame or other ignition source. P251 Pressurized container: Do not pierce or burn, even after use. P260 Do not breathe dust/fume/gas/mist/vapours/spray. P270 Do not eat, drink or smoke when using this product. P264 Wash all exposed external body areas thoroughly after handling.
Response
P307+P311 IF exposed: Call a POISON CENTER or doctor/physician.
Storage
P405 Store locked up. P410+P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F.
Disposal
P501 Dispose of contents/container in accordance with local regulations.