Brazing alloy ingot with cobalt, titanium and zirconium (Zr-Ti-Co Alloy Ingot)

Morgan Advanced Materials/Wesgo Metals

Revision date : 2016-04-21

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS08 GHS07 GHS02
Health risk rating 5
Safety risk rating 3
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

231-158-0/7440-48-4

Name of the chemical

Cobalt, Metall (2020/217)

Concentration

N/A

EC/CAS

231-176-9/7440-67-7

Name of the chemical

Zirconium and its compounds, with the exception of the substances listed under reference number 50 in Annex III, and the zirconium lakes, pigments or salts of the colouring agents when listed in Annex IV

Concentration

N/A

General Information

Revision date

2016-04-21

Product name

Brazing alloy ingot with cobalt, titanium and zirconium (Zr-Ti-Co Alloy Ingot)

Icons in SDS

GHS02 GHS07 GHS08

Company Information

company name

Morgan Advanced Materials/Wesgo Metals

e-mail address of the competent person responsible for the Safety Data Sheet

mtchayward.msds@morganplc.com

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H228, H317, H334, H351

Hazard statements

Code

Statements

H228

Flammable solid

H317

May cause an allergic skin reaction

H334

May cause allergy or asthma symptoms or breathing difficulties if inhaled

H351

Suspected of causing cancer

Section 2

SECTION 2: Hazards identification

Classification according to Regulation (EC) No. 1272/2008 [CLP As sold, braze alloys are solid articles (ingots, foil sheets and wire) and, therefore, are not considered hazardous until used in machining, grinding, melting and brazing operations, during which metal fumes and dust are generated. Metallic dust and thin sheets containing titanium and/or zirconium can cause a fire and/or explosion hazard. Alloys in powder form can create airborne dust during handling and use. Hazardous levels of dust or metal fumes of alloy constituents can create health risks, as described below. Classification

Hazard statements

H351 Suspected of causing cancer. H317 May cause allergic skin reaction. H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled. H228 Flammable solid. Note: Accompanying alpha-numeric designations included to address EU regulations.

Precautionary statements

P201 Obtain special instructions before use. P202 Do not handle until all safety precautions have been read and understood. P210 Keep away from heat/sparks/open flames/hot surfaces. – No smoking. P260 Do not breathe dust or fumes. P270 P280A + P264 Do not eat, drink or smoke when using this product. Wear protective gloves to prevent skin contact or thermal burns during brazing operations. Wash hands thoroughly after handling. P302 + P352 + If on skin: Wash with plenty of water. P333 + P313 If skin irritation or rash occurs: Get medical advice/attention. P304 + P312 If inhaled: Call a poison center or doctor if you feel unwell. P308 + P309 + P313 If exposed, concerned, or feel unwell: Get medical advice/attention. Other information about health hazards: Dust and fumes generated during brazing operations can cause skin and eye irritation. The materials in this product are not normally absorbed through the skin. Repeated or prolonged exposure to elevated concen- trations of any airborne dust or fume can irritate or harm the respiratory system, especially as an aggravation to a pre-existing condition. Inhalation of significant quantities of very fine metal dust and metal fumes can cause “metal fume fever,” with flu-like symptoms. Avoid creating and breathing airborne dust and fumes. Other information about physical hazards: Brazing and soldering operations present a fire hazard to nearby combustible materials. Finely dispersed metal particles can form ignitable and explosive mixtures in air. Maintain good housekeeping. –

2.1 Classification of the substance or mixture

Under the Globally Harmonized System of Classification and Labeling and the US OSHA Hazard Communication Standard, dust and fumes released during brazing operations are categorized as hazardous: (incl. Classification according to Regulation (EC) No 1272/2008 [CLP]) Carcinogenicity, Category 2 H351 due to the presence of cobalt Skin sensitizer, Category 1 H317 due to the presence of cobalt Respiratory sensitizer, Category 1 H334 due to the presence of cobalt Flammable solid, Category 2 H228 due to the presence of titanium and zirconium

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.