Note: Ingredients listed on restricted chemical lists
EC/CAS
9005-25-8
Name of the chemical
Starch
Concentration
2-5 <1
EC/CAS
14808-60-7
Name of the chemical
Silica, crystalline
Concentration
<1
General Information
Revision date
2025-02-01
Product name
Firemaster Board 350, Superwool Plus Aluboard, Superwool Plus Blok 1000, Superwool Plus Blok 1100, Superwool Plus Blok 800, Superwool Plus Board 75, Superwool PlusBoard 85, The above-mentioned products contain Alkaline-earth silicate wools (AES wools)
CAS No.
436083-99-7
REACH No
01-2119457644-32-0000
1.2.1 Relevant identified uses
Application as thermal insulation, heat shields, heat containment, gaskets and expansion joints in industrial furnaces, ovens, kilns, boilers and other process. equipment and in the aerospace, automotive and appliance industries, and as passive fire pro...
Icons in SDS
Company Information
company name
Morgan Advanced Materials
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H350I, H350i
Hazard statements
Code
Statements
H350i
May cause cancer by inhalation.
Section 2
SECTION 2: Hazards identification
Classified as hazardous according to criteria of Safe Work Australia. Classification of the substance/ mixture Classified as hazardous according to the criteria of Safework Australia as a category 1a Carcinogen Not classified as a dangerous good according to the criteria of the ADG Code
2.2 Label elements
Component
Hazard statements
Crystalline Silica Safework Australia GHS 08 H350I May cause cancer by inhalation (H350i)
Hazard pictograms
GHS 08
Signal word
Danger
Precautionary statements
not handle until all safety instructions have been read and understood. (P202) Use personal protective equipment as required. (P281)
Other hazards which do not result in classification
Mild mechanical irritation to skin, eyes and upper respiratory system may result from exposure. These effects are usually temporary. CHRONIC EFFECTS FOR CRYSTALLINE SILICA These products may contain minimal amounts of crystalline silica. Prolonged/repeated inhalation of respirable crystalline silica dust may cause delayed lung injury (silicosis). IARC (International Agency for Research on Cancer) states that there is "sufficient evidence in humans for the carcinogenicity of inhaled crystalline silica in the form of quartz or cristobalite from occupational sources to classify crystalline silica as carcinogenic to humans (Group 1)". (Monograph V 68) In making the overall evaluation the Working Group noted however that carcinogenicity in humans was not detected in all industrial circumstances studied.
2.1 Classification of the substance or mixture
Classified as hazardous according to the criteria of Safework Australia as a category 1a Carcinogen Not classified as a dangerous good according to the criteria of the ADG Code