GHS04
Health risk rating 2
Safety risk rating 4
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

7727-37-9

Name of the chemical

Nitrogen N2

Concentration

78.695-

General Information

Version

1.2

Revision date

2017-12-12

Product name

Oxygen (20.3 - 21.3%,) Nitrogen Dioxide (0.0001 - 0.005%,) in Nitrogen BalanceMSA P/N

supplier name

Mine Safety Appliances Company

Emergency telephone

1-800-424-9300, 1-703-527-3887

Icons in SDS

GHS04 T019

Company Information

company name

Mine Safety Appliances Company

GHS Information

Signal word

Warning

Hazard Codes

Hazard statements (CLP)

H280

Hazard statements

Code

Statements

H280

Contains gas under pressure; may explode if heated

Section 2

SECTION 2: Hazards identification

Classification (GHS-US)

Gases under pressure H280 Compressed gas Contains gas under pressure; may explode if heated

Hazard statements

see section 16 : H280 - Contains gas under pressure; may explode if heated CGA-HG24 - Supports combustion

2.2 Label elements

GHS-US labeling

Hazard pictograms

GHS04

Signal word

Warning

Precautionary statements

P202 - Do not handle until all safety precautions have been read and understood. P271 - Use only outdoors or in a well-ventilated area. P280 - Wear eye protection, face protection, protective gloves, protective clothing. P403 - Store in a well-ventilated place. P501 - Dispose of contents/container in accordance with local/regional/national/international regulations CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C/125 °F CGA-PG05 - Use a back flow preventive device in the piping CGA-PG06 - Close valve after each use and when empty CGA-PG10 - Use only with equipment rated for cylinder pressure CGA-PG14 - Approach suspected leak area with caution CGA-PG21 - Open valve slowly

Other hazards which do not result in classification

No additional information available 01/15/2018 EN (English US) SDS ID: 50022MSA Page 1

Ingredient(s) with unknown acute toxicity

Not applicable

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.