Health risk rating 1
Safety risk rating 1
Environmental risk rating 1

General Information

Revision date

2010-04-16

Product name

Adhesive ADH003-000

Icons in SDS

Company Information

company name

Midmos Solutions Ltd

Section 2

SECTION 2: Hazards identification

Directive 1999/45/EC: EMERGENCY OVERVIEW Not classified as dangerous. EYE As supplied irritant as a foreign body. As used severe thermal hazard SKIN CONTACT As supplied no hazard. As used severe thermal hazard INHILATION Vapours and/or aerosols which may be formed at elevated temperatures may Be irritating to eyes and respiratory tract. INGESTION Low oral toxicity. PHYSICO-CHEMICAL No unusual hazards are expected. ENVIROMENTAL Adverse effects would not be expected. 4. FIRST-AID MEASURE EYE If hot: flush with cool water. Treat as a wax or resin burn. Do not attempt to Remove solidified adhesive. Get medical attention immediately. As supplied: Remove as foreign body. SKIN CONTACT If hot: flush with cool water. Treat as a wax or resin burn. Do not attempt to Remove solidified adhesive. Get medical attention immediately. As supplied: Non hazardous. INHILATION Remove to fresh air. Get medical attention if irritation persists. INGESTION None required. 5. FIRE-FIGHTING MEASURES EXTINGUISHING MEDIA CO2; Dry Chemical SPECIAL FIREFIGHTING No special procedures are required. PROCEDURES FIRE & EXPLOSION HAZARDS Combustible at high temperatures. HAZARDOUS COMBUSTION Carbon monoxide, carbon dioxide, unknown hydrocarbons. PRODUCTS FLASH POINT 250°C 1 of 6 6. ACCIDENTAL RELEASE MEASURES SPILL AND LEAK Allow to cool and solidify. Scrape up and collect in suitable containers for disposal. PROCEDURES For safety and environmental precautions, please review entire Safety Data Sheet for necessary information. 7. HANDLING AND STORAGE HANDLING/STORAGE Store in a cool, dry area. Precaution: this product should only be heated to Recommended temperatures. The hazards of pyrolysis products are unknown. SENSITIVE TO STATIC No ELECTRICITY SPECIAL SENSITIVITY No special sensitivity. 8. EXPOSURE CONTROLS/PERSONAL PROTECTION VENTILATION Normal (mechanical) room ventilation should be adequate for small volumes. REQUIREMENTS For higher volume activities, or if needed for worker comfort, local mechanical Exhaust should be provided. EYE PROTECTION Safety glasses, goggles or face shield to protect against sp[lashing. Personal REQUIREMENTS eye protection should conform to EN166. GLOVE REQUIREMENTS Thermally resistant gloves should be worn. CLOTHING REQUIREMENTS Uniforms, coveralls or a lab coat should be worn. RESPIRATORY None required if good ventilation is maintained. REQUIREMENTS 9. PHYSICAL AND CHEMICAL PROPERTIES PURE SUBSTANCE OR PREPARATION Preparation. PHYSICAL FORM Solid. COLOUR Yellow. ODOUR Slight. BOILING POINT 250°C MELTING/FREEZING POINT ca.120°C SOLUBILITY IN WATER 250°C 10. STABILITY AND REACTIVITY STABILITY Stable Not applicable.

TOXICOLOGICAL INFORMATION

EYE As supplied irritant as a foreign body. As used severe thermal hazard SKIN As supplied no hazard. As used severe thermal hazard INHILATION Vapours and/or aerosols which may be formed at elevated temperatures May be irritating to eyes and respiratory tract. INGESTION Low oral toxicity. EFFECTS OF CHRONIC Although this product has not been tested for chronic effects it is judged as EXPOSURE having a low order of toxicity based on component information. Use of good Industrial hygiene practises are recommended. TARGET ORGANS None known. PRODUCT INFORMATION Not established.

ECOLOGICAL INFORMATION

POTENTIAL EFFECT ON.ENVIRONMENT Unknown. ECOTOXICITY Unknown. MOBILITY Unknown. PERSISTANCE AND DEGRADABILITY Unknown. POTENTIAL TO BIOACCUMULATE No 2 of 6 13. DISPOSAL CONSIDERATIONS WASTE DISPOSAL METHODS Waste disposal should be in accordance with existing Community, National and local regulations. EMPTY CONTAINER WARNINGS Not needed. 14. TRANSPORT INFORMATION (see also section 9)

IATA CLASSIFICATION

Not classified as dangerous. IMDG CLASSIFICATION Not classified as dangerous. ADR/RID Not classified as dangerous. 15. REGULATORY INFORMATION Not classified as dangerous EINECS All components of this product are listed in EINECS or ELINCS.

Further information

Revision 18/04/2006 REPLACES VERSION DATED 13/07/2004 ORIGINAL DOCUMENT DATED 10/07/2003 CHANGES SINCE PREVIOUS ISSUE INFORMATION, CONTACT Telephone +44 (0) 1384472900 No components which pose a risk. Directives 1999/45/EC and 91/155/EEC have been considered when compiling this SDS; the information is provided for health and safety assessment by an industrial user. Reference should be made to any relevant local or national health , safety and environmental legislation. This information does not constitute indication of suitability for specification uses. PLEASE SEE BELOW Active Base Monitor Adhesive 3 of 6 BB Alert® Active Base Monitor Adhesive Revision 04.03.2010 Revision 1 1.1 PRODUCT IDENTIFICATION: Adhesive ADH004-000 1.2 PRODUCT USE Monitor Adhesive 1.3 COMPANY: Midmos Solutions Ltd, 29, Navigation Drive Hurst Business Park, Brierley Hill, West Midlands. DY5 1UT. UK 1.4 EMERGENCY TELEPHONE: 0044(0)1384 472900 RISK PHRASES (R) None Identified The trap substrate contains no hazardous ingredients. The adhesive can be unpleasant to handle due to its sticky nature but represents a very low hazard. 3.0 COMPOSITION: CHEMICAL NAME OTHER NAMES Approx w/w % Hazard CAS EC / EINECS Trap substrate 68% Hot melt pressure sensitive 32% adhesive

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.