Note: Ingredients listed on restricted chemical lists
EC/CAS
138495-42-8
Name of the chemical
Pentane, 1,1,1,2,2,3,4,5,5,5-decafluoro
Concentration
N/A
General Information
Revision date
2020-09-09
Product name
Opteon Sion specialty fluid M2S-SIONGL, M2S-SIONGG, M2S-SIONG, M2S-SIONL, M2S-SIONP, M2S-SIOND, MicroCare Repackaged
supplier name
MICROCARE LLC
Manufacturer Name
MICROCARE LLC
Emergency telephone
1-800-424-9300 (within the U.S.
Icons in SDS
Company Information
company name
MICROCARE LLC
e-mail address of the competent person responsible for the Safety Data Sheet
techsupport@microcare.com
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H320, H332, H336, H412
Hazard statements
Code
Statements
H320
Causes eye irritation
H332
Harmful if inhaled
H336
May cause drowsiness or dizziness
H412
Harmful to aquatic life with long lasting effects
Section 2
2.1 Classification of the substance or mixture
OSHA Regulatory Status This Product is Hazardous under the OSHA Hazard Communication Standard.
Physical hazards
Not Classified
Health hazards
Eye Irrit. 2B - H320 STOT SE 3 - H336
Environmental hazards
Aquatic Chronic 3 - H412 Human health Irritating to eyes. Physicochemical Vapors are heavier than air and may travel along the floor and accumulate in the bottom of containers.
Signal word
Warning
Hazard statements
H332 Harmful if inhaled. H320 Causes eye irritation. H336 May cause drowsiness or dizziness. H412 Harmful to aquatic life with long lasting effects.
Precautionary statements
P261 Avoid breathing vapor/ spray. P264 Wash contaminated skin thoroughly after handling. P271 Use only outdoors or in a well-ventilated area. P273 Avoid release to the environment. P305+P351+P338 If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P312 Call a poison center/ doctor if you feel unwell. P337+P313 If eye irritation persists: Get medical advice/ attention. P403+P233 Store in a well-ventilated place. Keep container tightly closed. P501 Dispose of contents/ container in accordance with national regulations.
Supplemental label elements
Safety data sheet available on request. For use in industrial installations only. information
2.3 Other hazards
This product does not contain any substances classified as PBT or vPvB.