Note: Ingredients listed on restricted chemical lists
EC/CAS
203-492-7/107-46-0
Name of the chemical
Hexamethyldisiloxane
Concentration
60-90%
EC/CAS
212-377-0/811-97-2
Name of the chemical
1,1,1,2-Tetrafluoroethane
Concentration
10-30%
General Information
Version
10
Revision date
2014-01-28
Product name
DC1 - N0-CLEAN FLUX REMOVER - VERICLEAN, AEROSOL
Product name
DC1 - N0-CLEAN FLUX REMOVER - VERICLEAN, AEROSOL
Identification on the label/Trade name
"DC1 - VeriClean Defluxer/Degreaser, Plastic Safe"
supplier name
MicroCare Corporation
Emergency telephone
(800) 424-9300
Icons in SDS
Company Information
company name
MicroCare Corporation
e-mail address of the competent person responsible for the Safety Data Sheet
techsupport@microcare.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H222, H400
Hazard statements
Code
Statements
H222
Extremely flammable aerosol
Section 2
SECTION 2: Hazards identification
OSHA Hazards EMERGENCY OVERVIEW FLAMMABLE. Aerosol containers can explode when heated, due to excessive pressure build-up. Cool aerosol containers exposed to heat with water spray and remove container, if no risk is involved. Vapors are heavier than air and may travel along the floor and in the bottom of containers. Keep out of the reach of children. Appearance Liquid Color Clear Colourless. Odor Slight odor. Ether.
Signal word
Danger
Hazard statements
H222 Extremely flammable aerosol. H400 Very toxic to aquatic life.
Precautionary statements
P210 Keep away from heat/sparks/open flames/hot surfaces. – No smoking. P211 Do not spray on an open flame or other ignition source. P251 Pressurized container: Do not pierce or burn, even after use. P273 Avoid release to the environment. P410+412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122°F. P501 Dispose of contents/container in accordance with local regulations.
Other physicochemical hazards
Flam. Aerosol 1 - H222 Human health Not classified. Pressurized container: protect from sunlight and do not expose to temperatures exceeding 50°C. Do not pierce or burn, even after use.
Environmental hazards
Aquatic Acute 1 - H400 WORKPLACE HAZARDOUS MATERIALS INFORMATION SYSTEM
Other Health Effects
This substance has no evidence of carcinogenic properties.