Note: Ingredients listed on restricted chemical lists
EC/CAS
102687-65-0
Name of the chemical
1-Propene, 1-chloro-3,3,3-trifluoro-, (1E)
Concentration
N/A
EC/CAS
29118-24-9
Name of the chemical
(E)-1,3,3,3-Tetrafluoro-1-propene
Concentration
N/A
EC/CAS
67-56-1
Name of the chemical
Methanol
Concentration
N/A
EC/CAS
108-10-1
Name of the chemical
4-methylpentan-2-one; isobutyl methyl ketone (MIBK)
Concentration
N/A
EC/CAS
141-78-6
Name of the chemical
acetic acid, ethyl ester
Concentration
N/A
General Information
Revision date
2019-05-28
Product name
CCH UNIVERSAL CONTACT CLEANER, AEROSOL
supplier name
MICROCARE CORPORATION
Manufacturer Name
MICROCARE CORPORATION
Icons in SDS
Company Information
company name
MICROCARE CORPORATION
e-mail address of the competent person responsible for the Safety Data Sheet
techsupport@microcare.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H229, H360
Hazard statements
Code
Statements
H229
Pressurized container: may burst if heated
Section 2
2.1 Classification of the substance or mixture
OSHA Regulatory Status This Product is Hazardous under the OSHA Hazard Communication Standard.
Physical hazards
Not Classified
Health hazards
Repr. 1B - H360
Environmental hazards
Not Classified Human health Prolonged or repeated contact with skin may cause irritation, redness and dermatitis. Mild dermatitis, allergic skin rash. Environmental The product contains a substance which is harmful to aquatic organisms and which may cause long-term adverse effects in the aquatic environment. Physicochemical Vapors are heavier than air and may travel along the floor and accumulate in the bottom of containers. Not considered to be a significant hazard due to the small quantities used. Gas or vapor displaces oxygen available for breathing (asphyxiant). H229 Pressurised container: may burst if heated
Signal word
Danger
Hazard statements
H360 May damage fertility or the unborn child.
Precautionary statements
P210 Keep away from heat, sparks, open flames and hot surfaces. No smoking. P211 Do not spray on an open flame or other ignition source. P251 Pressurized container: Do not pierce or burn, even after use P280 Wear protective gloves/ protective clothing/ eye protection/ face protection. P410+P412 Protect from sunlight. Do not expose to temperatures exceeding 50°C /122°F. P501 Dispose of contents/ container in accordance with national regulations.
Supplemental label elements
Safety data sheet available on request. For use in industrial installations only. information
Contains
METHANOL