Note: Ingredients listed on restricted chemical lists
EC/CAS
811-97-2
Name of the chemical
1,1,1,2-Tetrafluoroethane
Concentration
90.0-100.0 0-20.0 43.00-53.00
EC/CAS
67-63-0
Name of the chemical
Propan-2-ol
Concentration
43.00-53.00
EC/CAS
67-56-1
Name of the chemical
Methanol
Concentration
200 ppm
General Information
Product name
ProClean Flux Remover
Product Synonyms
isopropanol In the aerosol form, tetrafluoroethane is used as a
Chemical name
Blended proprietary denatured alcohol and
Icons in SDS
Company Information
company name
MICRO CARE CORPORATION
e-mail address of the competent person responsible for the Safety Data Sheet
techsupport@microcare.com
Section 2
SECTION 2: Hazards identification
Emergency Overview: Flammable Liquid. Colorless liquid with an alcohol odor. Liquid will irritate eyes and skin under repeated or prolonged exposure. Product vapors can be moved by air currents and ignited by pilot lights, other flames, sparks, heaters, electrical equipment, static discharges or other ignition sources distant from product handling point. Keep away from children.
Potential health effects
Eyes Vapor contact Mild irritant. Liquid contact Will irritate eyes with possible corneal injury. Persons wearing contact lenses should wear chemical protective safety glasses when exposed to this product. Skin For repeated contact dry/chapped skin, risk of chronic dermatitis Ingestion: Can cause depression of central nervous system, nausea, stomach cramps, vomiting, diarrhea. Individual responses to methanol vary. Ingestion of less than 30 ml (0.34g/kg) of methanol has been fatal to humans. In general, a few ounces of methanol may cause blindness and death; as little a 4 ml. may be toxic if ingested. Inhalation At low concentration levels may cause mild irritation to nose and throat. At high levels: headache, drowsiness and lassitude, loss of appetite, inability to concentrate.
Medical Conditions Generally Aggravated by Exposure
Preexisting disease of the heart, lungs, skin and eyes.