Note: Ingredients listed on restricted chemical lists
EC/CAS
231-157-5/7440-47-3
Name of the chemical
Chromium; chromic acid and its salts
Concentration
5-<10%
EC/CAS
232-188-7/7789-75-5
Name of the chemical
Calcium fluoride
Concentration
5-<10%
EC/CAS
238-878-4/14808-60-7
Name of the chemical
Silica, crystalline
Concentration
1-<5%
EC/CAS
215-687-4/1344-09-8
Name of the chemical
Silicic acid, sodium salt
Concentration
1-<5%
EC/CAS
231-105-1/7439-96-5
Name of the chemical
Manganese
Concentration
1-<5%
EC/CAS
236-675-5/13463-67-7
Name of the chemical
Reaction mass of titanium dioxide and silver chloride
Concentration
0,1-<1%
EC/CAS
215-108-5/1302-78-9
Name of the chemical
bentonite
Concentration
0,1-<1%
EC/CAS
231-545-4/7631-86-9
Name of the chemical
Silver adsorbed on silicon dioxide
Concentration
0,1-<1%
EC/CAS
9004-62-0
Name of the chemical
hydroxyethylcellulose
Concentration
0,1-<1%
EC/CAS
231-111-4/7440-02-0
Name of the chemical
Nickel
Concentration
0,1-<1%
EC/CAS
215-279-6
Name of the chemical
Calcium carbonate
Concentration
5-<10%
EC/CAS
215-183-4
Name of the chemical
Lithium hydroxide
Concentration
0,1-<1%
General Information
Version
10.0
Revision date
2024-02-23
Product name
CHROMET 9
1.2.1 Relevant identified uses
SMAW (Shielded Metal Arc Welding)
1.2.2. Uses advised against
Not known. Read this SDS before using this product
Emergency telephone
+1 (888) 609-1762, +1 (216) 383-8962, +1 (216) 383-8966, +1 (216) 383-8969
Icons in SDS
Company Information
company name
Metrode Products Ltd
GHS Information
Signal word
Warning
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
The product has not been classified as hazardous according to the legislation in force.
2.2 Label elements
Not applicable
Supplemental label elements
EUH210: Safety data sheet available on request. Safety data sheet available for professional user on request.
2.3 Other hazards
Electrical Shock can kill. If welding must be performed in damp locations or with wet clothing, on metal structures or when in cramped positions such as sitting, kneeling or lying, or if there is a high risk of unavoidable or accidental contact with work piece, use the following equipment: Semiautomatic DC Welder, DC Manual (Stick) Welder, or AC Welder with Reduced Voltage Control. Arc rays can injure eyes and burn skin. Welding arc and sparks can ignite combustibles and flammable materials. Overexposure to welding fumes and gases can be hazardous. Read and understand the manufacturer’s instructions, Safety Data Sheets and the precautionary labels before using this product. Refer to Section 8. Substance(s) formed under The welding fume produced from this welding electrode may contain the the conditions of use: following constituent(s) and/or their complex metallic oxides as well as solid particles or other constituents from the consumables, base metal, or base metal coating not listed below. Chemical name CAS-No. Carbon dioxide 124-38-9 Carbon monoxide 630-08-0 Nitrogen dioxide 10102-44-0 Ozone 10028-15-6 Manganese 7439-96-5 Chromium (VI) 18540-29-9 Nickel 7440-02-0 Chromium oxide 1308-38-9 Fluorides (as F) 16984-48-8