Note: Ingredients listed on restricted chemical lists
EC/CAS
7440-22-4
Name of the chemical
Silver
Concentration
N/A
EC/CAS
7440-50-8
Name of the chemical
Copper
Concentration
N/A
EC/CAS
231-131-3
Name of the chemical
Colloidal silver (nano) [INCI] (11)
Concentration
N/A
EC/CAS
231-159-6
Name of the chemical
Copper (nano) [INCI] (11), Colloidal Copper (nano) [INCI] (11)
Concentration
N/A
General Information
Revision date
2014-09-01
Product name
MG: 112, 114, 116
supplier name
N94 W14355 GARWIN MACE DRIVE
Manufacturer Name
MESSER - MG WELDING PRODUCTS
Icons in SDS
Company Information
company name
MESSER - MG WELDING PRODUCTS
GHS Information
Signal word
WARNING
Section 2
SECTION 2: Hazards identification
GHS Classification EMERGENCY OVERVIEW Chemically stable and inert. Does not pose a fire hazard as shipped. Non-Flammable Flames used for brazing can ignite combustibles. Refer to American National Standard Z49.1 for fire prevention during welding. These products as shipped are non-hazardous, nonflammable, non-explosive, and non-reactive. In case of fire, Use NIOSH/MSHA self contained breathing apparatus.
Principle Routes of Exposure
Primary route of entry is the respiratory system. Other possible routes are eyes and/or skin contact WARNING This product contains or produces a chemical known to the State of California to cause birth defects (or other reproductive harm) and cancer. (California Health & Safety Code 25249.5 et seq.). WARNING: avoid breathing welding fumes and gases; they may dangerous to your health. Always use adequate ventilation and use appropriate personal protection equipment. CARCINOGENICITY WELDING FUMES (not otherwise specified) are considered to be carcinogenic defined with no further categorization by NIOSH and IARC.
2.1 Classification of the substance or mixture
Not applicable
Hazard statements
May cause sensitization of susceptible persons by skin contact.
Precautionary statements
P285 In case of inadequate ventilation wear respiratory protection. P314 Get medical advice/attention if you feel unwell. P280 Wear protective gloves/protective clothing/eye protection/face protection. P202 Do not handle until all safety precautions have been read and understood. P260 Do not breathe dust/fume/gas/mist/vapors/spray. P501 Dispose of contents/container to waste treatment facility in accordance with local and national regulations. Before using this product, contact your doctor to determine if exposure to product or use of this product will aggravate your medical conditions. Spatter and flames from brazing may cause burns and start fires.