General Information
Version
8.8
Revision date
2024-07-02
Product name
Cyclohexanol for synthesis
CAS No.
108-93-0
1.2.1 Relevant identified uses
For R&D use only. Not for pharmaceutical, household or other uses 1.4
Emergency telephone
+64 9 801 0034
Icons in SDS
Company Information
company name
Merck Life Science Ltd
e-mail address of the competent person responsible for the Safety Data Sheet
customersupport.anz@merckgroup.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H227, H302, H302+H312+H332, H312, H319, H332, H335, H360, H412
Hazard statements
Code
Statements
H227
Combustible liquid
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
Flammable liquids (Category 4), H227 Acute toxicity, Oral (Category 4), H302 Acute toxicity, Inhalation (Category 4), H332 Acute toxicity, Dermal (Category 4), H312 Serious eye damage/eye irritation (Category 2), H319 Reproductive toxicity (Category 1), H360 Specific target organ toxicity - single exposure (Category 3), Respiratory system, H335 Hazardous to the aquatic environment - chronic hazard (Category 3), H412 For the full text of the H-Statements mentioned in this Section, see Section 16.
Signal word
Danger
Hazard statements
H227 Combustible liquid. H302 + H312 + H332 Harmful if swallowed, in contact with skin or if inhaled. H319 Causes serious eye irritation. H335 May cause respiratory irritation. H360 May damage fertility or the unborn child. H412 Harmful to aquatic life with long lasting effects.
Prevention
P201 Obtain special instructions before use. P202 Do not handle until all safety precautions have been read and understood. P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P264 Wash skin thoroughly after handling. P280 Wear protective gloves/ protective clothing/ eye protection/ face protection.
Response
P308 + P313 IF exposed or concerned: Get medical advice/ attention. P370 + P378 In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish.
Storage
P403 + P233 Store in a well-ventilated place. Keep container tightly closed. P405 Store locked up.
Disposal
P501 Dispose of contents/ container to an approved waste disposal plant.
Other hazards
- none