Note: Ingredients listed on restricted chemical lists
EC/CAS
7732-18-5
Name of the chemical
Water, distilled, conductivity or of similar purity H2O
Concentration
N/A
General Information
Revision date
2010-07-19
Product name
D156, Express Spray Wax (DX-93A)
CAS No.
7732-18-5
Manufacturer Name
Meguiar’s, Inc
Emergency telephone
Within USA and Canada 1-800-424-9300
Icons in SDS
Company Information
company name
Meguiar’s, Inc
Section 2
SECTION 2: Hazards identification
3.1 EMERGENCY OVERVIEW Odor, Color, Grade: Moderately sweet odor; Light, milky liquid General Physical Form: Liquid Immediate health, physical, and environmental hazards: May cause allergic skin reaction.
Potential health effects
Eye Contact: Sprayed material may cause eye irritation. Signs/symptoms may include redness, swelling, pain, tearing, and blurred or hazy vision. Skin Contact: Contact with the skin during product use is not expected to result in significant irritation. Allergic Skin Reaction (non-photo induced): Signs/symptoms may include redness, swelling, blistering, and itching. Inhalation: Sprayed material may cause irritation of the respiratory system. Signs/symptoms may include cough, sneezing, nasal discharge, headache, hoarseness, and nose and throat pain. Ingestion: No health effects are expected. SECTION 4: FIRST AID MEASURES 4.1 FIRST AID PROCEDURES The following first aid recommendations are based on an assumption that appropriate personal and industrial hygiene practices are followed. Eye Contact: Flush eyes with large amounts of water. If signs/symptoms persist, get medical attention. Skin Contact: Remove contaminated clothing and shoes. Immediately flush skin with large amounts of water. Get medical attention. Wash contaminated clothing and clean shoes before reuse. Inhalation: If signs/symptoms develop, remove person to fresh air. If signs/symptoms persist, get medical attention. No need for first aid is anticipated. If Swallowed: No need for first aid is anticipated. SECTION 5: FIRE FIGHTING MEASURES 5.1 FLAMMABLE PROPERTIES Autoignition temperature Not Applicable Flash Point Not Applicable Flammable Limits - LEL Not Applicable Flammable Limits - UEL Not Applicable 5.2 EXTINGUISHING MEDIA Material will not burn. 5.3 PROTECTION OF FIRE FIGHTERS Special Fire Fighting Procedures: Wear full protective equipment (Bunker Gear) and a self-contained breathing apparatus (SCBA). Unusual Fire and Explosion Hazards: No unusual fire or explosion hazards are anticipated. Note: See STABILITY AND REACTIVITY (SECTION 10) for hazardous combustion and thermal decomposition information. SECTION 6: ACCIDENTAL RELEASE MEASURES Personal precautions Evacuate unprotected and untrained personnel from hazard area. The spill should be cleaned up by qualified personnel. Ventilate the area with fresh air. For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapors, in accordance with good industrial hygiene practice. Warning! A motor could be an ignition source and could cause flammable gases or vapors in the spill area to burn or explode. Environmental procedures For larger spills, cover drains and build dikes to prevent entry into sewer systems or bodies of water. Place in a closed container approved for transportation by appropriate authorities. Dispose of collected material as soon as possible. Clean-up methods Observe precautions from other sections. Contain spill. Working from around the edges of the spill inward, cover with bentonite, vermiculite, or commercially available inorganic absorbent material. Mix in sufficient absorbent until it appears dry. Collect as much of the spilled material as possible. Clean up residue with water. In the event of a release of this material, the user should determine if the release qualifies as reportable according to local, state, and federal regulations. SECTION 7: HANDLING AND STORAGE 7.1 HANDLING For industrial or professional use only. Avoid breathing of vapors, mists or spray. Avoid skin contact. Avoid eye contact with vapors, mists, or spray.
Storage
Store under normal warehouse conditions. SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION 8.1 ENGINEERING CONTROLS Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below Occupational Exposure Limits and/or control mist, vapor, or spray. If ventilation is not adequate, use respiratory protection equipment. 8.2 PERSONAL PROTECTIVE EQUIPMENT (PPE) 8.2.1 Eye/Face Protection Avoid eye contact with vapors, mists, or spray. 8.2.2 Skin Protection Avoid skin contact. Select and use gloves and/or protective clothing to prevent skin contact based on the results of an exposure assessment. Consult with your glove and/or protective clothing manufacturer for selection of appropriate compatible materials. 8.2.3 Respiratory Protection Avoid breathing of vapors, mists or spray. 8.2.4 Prevention of Swallowing Not an expected route of exposure. 8.3 EXPOSURE GUIDELINES Ingredient Authority Type Limit Additional Information CONDITIONERS ACGIH TWA, as fume 2 mg/m3 SOURCE OF EXPOSURE LIMIT DATA: ACGIH: American Conference of Governmental Industrial Hygienists CMRG: Chemical Manufacturer Recommended Guideline OSHA: Occupational Safety and Health Administration AIHA: American Industrial Hygiene Association Workplace Environmental Exposure Level (WEEL)