General Information
Version
2.0
Revision date
2016-04-22
Product name
POWER UP PENETRATING FLUID 2000 AEROSOL
1.2.1 Relevant identified uses
Use as an anti-seize lubricant
1.2.2. Uses advised against
Do Not Mix with Alcohol Based or Glycol Based Products
Manufacturer Name
WYS Manufacturing Ltd
Emergency telephone
1-403-252-2239, 1-613-996-6666
Icons in SDS
Company Information
company name
Maryn International Ltd
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H304, H351, H360
Hazard statements
Code
Statements
H304
May be fatal if swallowed and enters airways
Section 2
SECTION 2: Hazards identification
GHS Classification GHS Classification
Aspiration hazard
Category 1 Carcinogenicity: Reproductive Toxicity Category 2 Category 1B
Signal word
Danger Warning
Hazard statements
H304 May be fatal if swallowed and enters airways. H351 Suspected of causing cancer. H360 May damage fertility or the unborn child.
2.3 Other hazards
None
Prevention
P201 Obtain special instructions before use. P202 Do no handle until all safety precautions have been read and understood. P280 Wear protective gloves/protective clothing/eye protection/face protection.
Response
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/DOCTOR P308 + P313 IF exposed or concerned: Get medical advice/attention. P331 Do NOT induce vomiting.
Disposal
P501 Dispose of contents/ container to an approved waste disposal plant.
Storage
P405 Store locked up. P411+235: Store at temperatures not exceeding 190°C/374 °F. Keep cool. Symptoms of Overexposure May cause skin irritation and eye irritation. May lead to dermatitis. Carcinogenicity N/A
2.1 Classification of the substance or mixture
Aspiration Hazard: Category 1 Carcinogenicity: Category 2 Reproductive Toxicity: Category 1B