MarkWest Natural Gas Condensate (High RVP)

MarkWest Energy Partners, L.P a subsidiary of MPLX LP

Revision date : 2019-10-08

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS02 GHS04 GHS07 GHS09
Health risk rating 5
Safety risk rating 5
Environmental risk rating 5

Note: Ingredients listed on restricted chemical lists

EC/CAS

68919-39-1

Name of the chemical

Natural gas condensates; Low boiling point naphtha — unspecified (A complex combination of hydrocarbons separated and/or condensed from natural gas during transportation and collected at the wellhead and/or from the production, gathering, transmission, and distribution pipelines in deeps, scrubbers, etc. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C2 through C8.)

Concentration

N/A

EC/CAS

106-97-8

Name of the chemical

n-Butan, enthält  0,1% Butadien

Concentration

N/A

EC/CAS

109-66-0

Name of the chemical

pentane

Concentration

N/A

EC/CAS

110-54-3

Name of the chemical

n-Hexan (790/2009)

Concentration

N/A

EC/CAS

110-82-7

Name of the chemical

Cyclohexane

Concentration

N/A

EC/CAS

91-20-3

Name of the chemical

Naphthalene,3

Concentration

N/A

EC/CAS

100-41-4

Name of the chemical

Ethylbenzene

Concentration

N/A

Listed in

EC/CAS

98-82-8

Name of the chemical

Cumol (2022/692)

Concentration

N/A

EC/CAS

124-38-9

Name of the chemical

Carbon dioxide CO2

Concentration

N/A

General Information

Revision date

2019-10-08

Product name

MarkWest Natural Gas Condensate (High RVP)

Product Synonyms

Natural gas condensate; High RVP natural gas condensate

Chemical name

Hydrocarbon Mixture

1.2.1 Relevant identified uses

Hydrocarbon

Emergency telephone

1-800-424-9300

Icons in SDS

Company Information

company name

MarkWest Energy Partners, L.P a subsidiary of MPLX LP

GHS Information

Signal word

Danger

Section 2

2.1 Classification of the substance or mixture

OSHA Regulatory Status This chemical is considered hazardous by the 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200) Flammable gases Category 1 Gases under pressure Liquefied Gas Simple asphyxiant - Germ cell mutagenicity Category 1B Carcinogenicity Category 1A Reproductive toxicity Category 2 Specific target organ toxicity (single exposure) Category 3 Specific target organ toxicity (repeated exposure) Category 1 Category 2 Chronic aquatic toxicity Category 2

2.3 Other hazards

Static accumulating flammable liquid Liquid product may cause freeze burn

2.2 Label elements

EMERGENCY OVERVIEW Danger Extremely flammable gas Contains gas under pressure; may explode if heated May accumulate electrostatic charge and ignite or explode May displace oxygen and cause rapid suffocation May cause drowsiness or dizziness Contact with liquid may cause frostbite May cause genetic defects May cause cancer Suspected of damaging fertility or the unborn child Causes damage to organs (blood, blood-forming organs, immune system) through prolonged or repeated exposure May cause damage to organs (nervous system, auditory system) through prolonged or repeated exposure Toxic to aquatic life with long lasting effects Appearance Liquefied Gas Physical State Gas Odor Aromatic

Prevention

Obtain special instructions before use Do not handle until all safety precautions have been read and understood Keep away from heat/sparks/open flames/hot surfaces. - No smoking Do not eat, drink or smoke when using this product Do not breathe gas/vapors Use only outdoors or in a well-ventilated area Wear protective gloves/protective clothing/eye protection/face protection Wash hands and any possibly exposed skin thoroughly after handling Avoid release to the environment

Response

If exposed, concerned or you feel unwell: Get medical attention If inhaled: Remove person to fresh air and keep comfortable for breathing. Call a poison center or doctor if you feel unwell Leaking gas fire: Do not extinguish, unless leak can be stopped safely Eliminate all ignition sources if safe to do so Collect spillage

Storage

Store in a well-ventilated place. Keep container tightly closed Protect from sunlight Store locked up

Precautionary statements

Disposal Dispose of contents/container at an approved waste disposal plant

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.