Note: Ingredients listed on restricted chemical lists
EC/CAS
7440-02-0
Name of the chemical
Nickel
Concentration
20-40%
EC/CAS
7440-48-4
Name of the chemical
Cobalt, Metall (2020/217)
Concentration
N/A
EC/CAS
7440-66-6
Name of the chemical
Zinc ()
Concentration
74420-02- 5-15%
EC/CAS
1333-86-4
Name of the chemical
Carbon black
Concentration
0-1%
EC/CAS
1310-58-3
Name of the chemical
Potassium or sodium hydroxide (20)
Concentration
0-15%
EC/CAS
1310-73-2
Name of the chemical
Potassium or sodium hydroxide (20)
Concentration
N/A
General Information
Revision date
2014-12-08
Product name
Nickel Metal Hydride Battery Complies with the OSHA Hazard
Emergency telephone
1-510-657-9881, 1-800-424-9300
Icons in SDS
Company Information
company name
Makita U.S.A., Inc.
Section 2
SECTION 2: Hazards identification
Most important adverse effects
and Effects The battery cell, chemical materials are stored in a hermetically sealed metal case, designed to withstand temperatures and pressures encountered during normal use. As a result, during normal use, there is no physical danger of ignition or explosion and chemical danger of hazardous materials leakage. However, if exposed to a fire, added mechanical shocks, decomposed, added electric stress by misuse, the gas release vent will be operated. The battery cell case will be breached at the extreme. Hazardous materials may be released. Moreover, if heated strongly by the surrounding fire, acrid or harmful fume may be emitted.
Potential health effects
Inhalation: The electrolyte inhalation affects the respiratory tract membrane and the lungs. Cadmium fume may cause a cough, chest pain and dyspnea. Bronchitis and pneumonia will be occurred. Probably, it is carcinogen Skin Contact: The electrolyte skin contact affects the skin seriously and may cause dermatitis. Eye Contact: The electrolyte leaked from the battery cell is strong alkali. When it goes into eye, the cornea may be affected and it may lead to blindness. Ingestion: The electrolyte ingestions irritates the mouth and the throat seriously results in vomiting, nausea, hematemesis, stomach pains and diarrhea.
Environmental effects
Since a battery cell remains in the environment, do not dispose it into the normal waste stream Specific Hazards: As previously described. 1