Note: Ingredients listed on restricted chemical lists
EC/CAS
235-362-0/12190-79-3
Name of the chemical
Cobaltate (CoO21-), lithium
Concentration
25-40
EC/CAS
231-072-3/7429-90-5
Name of the chemical
Aluminium
Concentration
2-6
EC/CAS
231-955-3/7782-42-5
Name of the chemical
Graphite
Concentration
10-20 7740-44- 101357-30-
EC/CAS
231-159-6/7440-50-8
Name of the chemical
Copper
Concentration
5-15 10-20
General Information
Revision date
2023-04-21
Product name
Lithium Ion battery cell Gx Battery Pack
Product Synonyms
None Company
Emergency telephone
1- 772-794-9448, 1- 772-589-9072, 1-772-794-9448
Icons in SDS
Company Information
company name
M. C. Miller Co., Inc.
e-mail address of the competent person responsible for the Safety Data Sheet
sales@mcmiller.com
Section 2
SECTION 2: Hazards identification
For the battery cell, Chemical materials are stored in a hermetically sealed metal case, designed to withstand temperatures and pressures encountered during normal use. As a result during normal use, there is no physical danger of ignition or explosion and chemical danger of hazardous material leakage. However, if exposed to a fire, added mechanical shocks, decomposed, added electric stress of miss-us, the gas release vent will be operated, The battery cell case will be breached at the extreme, hazardous material may be released. Moreover, if heated strongly by the surrounding fire, acrid gas may be emitted.
Most important adverse effects
and effects
Potential health effects
Inhalation: The steam of the electrolyte has an anesthesia and stimulates a respiratory tract. Skin contact: The steam of the electrolyte stimulates the skin. The electrolyte skin contact causes a sore and stimulation on the skin. Eye contact: The steam of the electrolyte stimulates eyes. The electrolyte eye contact causes a sore and stimulation on the eye. Especially, substance that causes a strong inflammation of the eye is contained.
Environmental effects
Since a battery cell remains in the environment, do not throw it out in the environment. Special hazards: If the electrolyte contacts with water, it will generate detrimental hydrogen fluoride. Since the leaked electrolyte is inflammable liquid, do not bring close to fire