Note: Ingredients listed on restricted chemical lists
EC/CAS
13463-67-7
Name of the chemical
Reaction mass of titanium dioxide and silver chloride
Concentration
N/A
EC/CAS
7440-48-4
Name of the chemical
Cobalt, Metall (2020/217)
Concentration
N/A
General Information
Revision date
2016-08-10
Product name
LORD PCD40566
1.2.1 Relevant identified uses
Dielectric Paste
Icons in SDS
Company Information
company name
LORD Corporation
GHS Information
Signal word
DANGER
Section 2
2.1 Classification of the substance or mixture
Skin corrosion/irritation Category 2 Serious eye damage/eye irritation Category 2A Skin sensitization Category 1 Respiratory sensitization Category 1 Carcinogenicity Category 2 Reproductive toxicity Category 2 Specific target organ systemic toxicity (single exposure) Category 3 Specific target organ systemic toxicity (single exposure) Category 2 Central nervous system Specific target organ systemic toxicity (repeated exposure) Category 1 Respiratory system Hazardous to the aquatic environment - acute hazard Category 2 Hazardous to the aquatic environment - chronic hazard Category 2
Signal word
DANGER
Hazard statements
Causes skin irritation. Causes serious eye irritation. May cause an allergic skin reaction. May cause allergy or asthma symptoms or breathing difficulties if inhaled. Suspected of causing cancer. Suspected of damaging fertility or the unborn child. May cause respiratory irritation. May cause damage to organs.(Central nervous system) Causes damage to organs through prolonged or repeated exposure.(Respiratory system) Toxic to aquatic life. Toxic to aquatic life with long lasting effects.
Prevention
Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. 300001002058 Wear protective gloves/eye protection/face protection. Use personal protective equipment as required. In case of inadequate ventilation wear respiratory protection. Do not breathe dust/fume/gas/mist/vapors/spray. Wash thoroughly after handling. Do not eat, drink or smoke when using this product. Use only outdoors or in a well-ventilated area. Contaminated work clothing should not be allowed out of the workplace. Avoid release to the environment.
Response
Call a POISON CENTER or doctor/physician if you feel unwell. Call a POISON CENTER or doctor/physician if exposed or you feel unwell. Specific treatment (see supplemental first aid instructions on this label). IF INHALED: Remove to fresh air and keep at rest in a position comfortable for breathing. If experiencing respiratory symptoms: Call a POISON CENTER or doctor/physician. IF ON SKIN: Wash with plenty of soap and water. If skin irritation or rash occurs: Get medical advice/attention. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Take off contaminated clothing and wash before reuse. Collect spillage.
Storage
Store in a well-ventilated place. Keep container tightly closed. Store locked up.
Disposal
Dispose of contents/container in accordance with waste/disposal laws and regulations of your country or particular locality.
2.3 Other hazards
This product contains component(s) which have the following warnings; however based on the GHS classification criteria of your country or locale, the product mixture may be outside the respective category(s). Acute: Harmful if absorbed through skin. May cause skin irritation. Harmful if swallowed. Ingestion is not an expected route of entry in industrial or commercial uses. Chronic: Prolonged or repeated contact may result in dermatitis. May cause liver or kidney damage. ACGIH considers molybdenum to be an A3 carcinogen (confirmed animal carcinogen with unknown relevance in humans). IARC has designated C.I. Pigment Blue 28 as Group 2B - inadequate evidence for carcinogenicity in humans, but sufficient evidence in experimental animals. IARC has designated cobalt to be in Group 2B - inadequate evidence for carcinogenicity in humans. IARC has designated titanium dioxide (TiO2) as Group 2B possibly carcinogenic to humans in dust form. However, a number of long term animal studies and human epidemiology studies evaluating TiO2 and workplace exposure show insufficient evidence for carcinogenic effects. EPA, NTP and OSHA do not designate TiO2 as a carcinogen and ACGIH designates TiO2 as A4 - not classifiable as a human carcinogen. Mortaility from other chronic diseases, including other respiratory diseases, was not associated with exposure to TiO2 dust. TiO2 is not present in this product as a dust and no airborne exposure is expected during application.