Note: Ingredients listed on restricted chemical lists
EC/CAS
7440-37-1
Name of the chemical
Argon Ar
Concentration
98.001 - 99
General Information
Version
1.0
Revision date
2025-10-17
Product name
PHOSPHINE (1% - 1.999%) IN ARGON
1.2.1 Relevant identified uses
Industrial and professional use
Emergency telephone
1-800-645-4633, 1-800-424-9300, 001-703-527-3887
Icons in SDS
Company Information
company name
Linde Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H220, H232, H250, H280, H315, H319, H331
Hazard statements
Code
Statements
H220
Extremely flammable gas
Section 2
SECTION 2: Hazards identification
Classification of the substance or mixture GHS-US classification Flam. Gas 1A - Pyr. Gas H220;H232 Press. Gas (Comp.) H280 Acute Tox. 3 (Inhalation:gas) H331 Skin Irrit. 2 H315 Eye Irrit. 2 H319
2.2 Label elements
GHS US labelling
Hazard pictograms
GHS02 GHS04 GHS06 GHS07
Signal word
Danger
Hazard statements
H220 - EXTREMELY FLAMMABLE GAS H250 - CATCHES FIRE SPONTANEOUSLY IF EXPOSED TO AIR H280 - CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED H315 - CAUSES SKIN IRRITATION H319 - CAUSES SERIOUS EYE IRRITATION H331 - TOXIC IF INHALED CGA-HG04 - MAY FORM EXPLOSIVE MIXTURES WITH AIR CGA-HG11 - SYMPTOMS MAY BE DELAYED
Precautionary statements
P202 - Do not handle until all safety precautions have been read and understood. P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P222 - Do not allow contact with air. P261 - Avoid breathing gas, vapours. EN (English) SDS ID: LIND-M0522 1/10 P271+P403 - Use and store only outdoors or in a well-ventilated place P280 - Wear protective gloves, protective clothing, eye protection, and face protection. P264 - Wash hands, forearms and face thoroughly after handling. P304+P340 - IF INHALED: Remove person to fresh air and keep comfortable for breathing. P311 - Call a poison center or doctor. P302+P352 - IF ON SKIN: Wash with plenty of water P362+P364 - Take off contaminated clothing and wash it before reuse. P332+P313 - If skin irritation occurs: Get medical advice or attention. P305+P351+P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P337+P313 - If eye irritation persists: Get medical advice or attention. P377 - LEAKING GAS FIRE: Do not extinguish, unless leak can be stopped safely. P381 - In case of leakage, eliminate all ignition sources. P405 - Store locked up. P501 - Dispose of contents/container in accordance with container supplier/owner instructions. CGA-PG05 - Use a back flow preventive device in the piping. CGA-PG10 - Use only with equipment rated for cylinder pressure. CGA-PG17 - Use only with equipment purged with inert gas or evacuated prior to discharge from cylinder. CGA-PG12 - Do not open valve until connected to equipment prepared for use. CGA-PG06 - Close valve after each use and when empty. CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F). CGA-PG18 - When returning cylinder, install leak tight valve outlet cap or plug.
2.3 Other hazards
No additional information available
Ingredient(s) with unknown acute toxicity
Not applicable
2.1 Classification of the substance or mixture
GHS-US classification Flam. Gas 1A - Pyr. Gas H220;H232 Press. Gas (Comp.) H280 Acute Tox. 3 (Inhalation:gas) H331 Skin Irrit. 2 H315 Eye Irrit. 2 H319