General Information
Version
2.3
Revision date
2022-02-23
Product name
MAPAX O
Product Synonyms
Oxygen, compressed
CAS No.
7782-44-7
Emergency telephone
1-800-645-4633, 1-800-424-9300, 001-703-527-3887
Icons in SDS
Company Information
company name
Linde Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H270, H280
Hazard statements
Code
Statements
H270
May cause or intensify fire; oxidiser
Section 2
SECTION 2: Hazards identification
Classification of the substance or mixture GHS-US classification Ox. Gas 1 H270 Press. Gas (Comp.) H280
2.2 Label elements
GHS US labelling
Hazard pictograms
GHS03 GHS04
Signal word
Danger
Hazard statements
H270 - MAY CAUSE OR INTENSIFY FIRE; OXIDIZER H280 - CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED
Precautionary statements
P202 - Do not handle until all safety precautions have been read and understood. P220 - Keep/Store away from combustible materials, clothing. P244 - Keep reduction valves/valves and fittings free from oil and grease. P271+P403 - Use and store only outdoors or in a well-ventilated place. P370+P376 - IN CASE OF FIRE: Stop leak if safe to do so CGA-PG05 - Use a back flow preventive device in the piping. CGA-PG20+CGA-PG10 - Use only with equipment of compatible materials of construction and rated for cylinder pressure. CGA-PG22 - Use only with equipment cleaned for oxygen service. EN (English) SDS ID: LIND-P097 1/9 CGA-PG12 - Do not open valve until connected to equipment prepared for use. CGA-PG21 - Open valve slowly. CGA-PG06 - Close valve after each use and when empty. CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F).
Other hazards which do not result in classification
Breathing 80 percent or more oxygen at atmospheric pressure for more than a few hours may cause nasal stuffiness, cough, sore throat, chest pain, and breathing difficulty. Breathing oxygen at higher pressure increases the likelihood of adverse effects within a shorter time period. Breathing pure oxygen under pressure may cause lung damage and central nervous system (CNS) effects, resulting in dizziness, poor coordination, tingling sensation, visual and hearing disturbances, muscular twitching, unconsciousness, and convulsions. Breathing oxygen under pressure may cause prolongation of adaptation to darkness and reduced peripheral vision.
Ingredient(s) with unknown acute toxicity
Not applicable
2.1 Classification of the substance or mixture
GHS-US classification Ox. Gas 1 H270 Press. Gas (Comp.) H280