General Information
Version
4.0
Revision date
2026-03-10
Product name
Hydrogen sulfide
Substance name
Hydrogen sulfide
CAS No.
7783-06-4
1.2.1 Relevant identified uses
Industrial and professional use
Emergency telephone
1-800-645-4633, 1-800-424-9300, 001-703-527-3887
Icons in SDS
Company Information
company name
Linde Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H220, H280, H330, H335, H400
Hazard statements
Code
Statements
H220
Extremely flammable gas
Section 2
SECTION 2: Hazards identification
Classification of the substance or mixture GHS-US classification Flam. Gas 1A H220 Press. Gas (Liq.) H280 Acute Tox. 2 (Inhalation:gas) H330 STOT SE 3 H335 Aquatic Acute 1 H400
2.2 Label elements
GHS US labelling
Hazard pictograms
GHS02 GHS04 GHS06 GHS07 GHS09
Signal word
Danger
Hazard statements
H220 - EXTREMELY FLAMMABLE GAS H280 - CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED CGA-HG04 - MAY FORM EXPLOSIVE MIXTURES WITH AIR H330 - FATAL IF INHALED H335 - MAY CAUSE RESPIRATORY IRRITATION CGA-HG16 - EXTENDED EXPOSURE TO GAS REDUCES THE ABILITY TO SMELL SULFIDES. CGA-HG11 - SYMPTOMS MAY BE DELAYED H400 - VERY TOXIC TO AQUATIC LIFE CGA-HG01 - MAY CAUSE FROSTBITE. EN (English) SDS ID: LIND-P071 1/10
Precautionary statements
P202 - Do not handle until all safety precautions have been read and understood. P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Heat, Open flames, Sparks, Hot surfaces P260 - Do not breathe gas. P262 - Do not get in eyes, on skin, or on clothing. P271+P403 - Use and store only outdoors or in a well-ventilated place P273 - Avoid release to the environment. P280+P284 - Wear protective gloves/protective clothing/eye protection/respiratory protection and/or face protection P377 - LEAKING GAS FIRE: Do not extinguish, unless leak can be stopped safely. P381 - In case of leakage, eliminate all ignition sources if safe to do so. P391 - Collect spillage. P405 - Store locked up. P501 - Dispose of in accordance with container supplier/owner instructions in accordance with container supplier/owner instructions. P304+P340 - IF INHALED: Remove person to fresh air and keep comfortable for breathing. P310 - Immediately call a doctor. P302, P336, P315 - IF ON SKIN: Thaw frosted parts with lukewarm water. Do not rub affected area. Get immediate medical advice/attention. CGA-PG29 - Do not depend on odour to detect the presence of gas. CGA-PG05 - Use a back flow preventive device in the piping. CGA-PG20+CGA-PG10 - Use only with equipment of compatible materials of construction and rated for cylinder pressure. CGA-PG12 - Do not open valve until connected to equipment prepared for use. CGA-PG18 - When returning cylinder, install leak tight valve outlet cap or plug. CGA-PG06 - Close valve after each use and when empty. CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F).
Other hazards which do not result in classification
Contact with liquid may cause cold burns/frostbite.
Ingredient(s) with unknown acute toxicity
Not applicable
2.1 Classification of the substance or mixture
GHS-US classification Flam. Gas 1A H220 Press. Gas (Liq.) H280 Acute Tox. 2 (Inhalation:gas) H330 STOT SE 3 H335 Aquatic Acute 1 H400