Note: Ingredients listed on restricted chemical lists
EC/CAS
7440-59-7
Name of the chemical
Helium He
Concentration
0 - 95
EC/CAS
7727-37-9
Name of the chemical
Nitrogen N2
Concentration
0 - 95
EC/CAS
7440-37-1
Name of the chemical
Argon Ar
Concentration
0 - 95
EC/CAS
7439-90-9
Name of the chemical
Krypton Kr
Concentration
0 - 95
EC/CAS
7647-01-0
Name of the chemical
Hydrochloric acid
Concentration
5 - 7
General Information
Version
1.5
Revision date
2024-02-15
Product name
HYDROGEN CHLORIDE (5-7%), HYDROGEN (<=2.9%) in ARGON, HELIUM, KRYPTON,NEON, or NITROGEN
Product Synonyms
NITROGEN
1.2.1 Relevant identified uses
Industrial and professional use
Emergency telephone
1-800-645-4633, 1-800-424-9300, 001-703-527-3887
Icons in SDS
Company Information
company name
Linde Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H280, H314, H318, H402
Hazard statements
Code
Statements
H280
Contains gas under pressure; may explode if heated
Section 2
SECTION 2: Hazards identification
Classification of the substance or mixture GHS-US classification Press. Gas (Comp.) H280 Skin Corr. 1A H314 Eye Dam. 1 H318 Simple asphyxiant SIAS Aquatic Acute 3 H402
2.2 Label elements
GHS US labelling
Hazard pictograms
GHS04 GHS05
Signal word
Danger
Hazard statements
H280 - CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED H314 - CAUSES SEVERE SKIN BURNS AND EYE DAMAGE CGA-HG22 - CORROSIVE TO THE RESPIRATORY TRACT. H402 - HARMFUL TO AQUATIC LIFE
Precautionary statements
P202 - Do not handle until all safety precautions have been read and understood. P260 - Do not breathe gas/vapours P264 - Wash exposed skin thoroughly after handling P273 - Avoid release to the environment. P280 - Wear protective gloves/protective clothing/eye protection/face protection. P405 - Store locked up. EN (English) SDS ID: LIND-M0108 1/13 P501 - Dispose of contents/container in accordance with container Supplier/owner instructions P271+P403 - Use and store only outdoors or in a well-ventilated place. CGA-PG05 - Use a back flow preventive device in the piping. CGA-PG10 - Use only with equipment rated for cylinder pressure. CGA-PG12 - Do not open valve until connected to equipment prepared for use. CGA-PG06 - Close valve after each use and when empty. CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F). P304+P340 - IF INHALED: Remove person to fresh air and keep comfortable for breathing. P305+P351+P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P310 - Immediately call a POISON CENTER/doctor. P303+P361+P353 - IF ON SKIN OR (HAIR): Take off immediately all contaminated clothing. Rinse skin with water/shower. P363 - Wash contaminated clothing before reuse. CGA-PG34 - SPECIFIC TREATMENT: Immediately apply calcium gluconate or equivalent to affected areas.
Other hazards which do not result in classification
Asphyxiant in high concentrations.
Ingredient(s) with unknown acute toxicity
Not applicable
2.1 Classification of the substance or mixture
GHS-US classification Press. Gas (Comp.) H280 Skin Corr. 1A H314 Eye Dam. 1 H318 Simple asphyxiant SIAS Aquatic Acute 3 H402