Note: Ingredients listed on restricted chemical lists
EC/CAS
7440-37-1
Name of the chemical
Argon Ar
Concentration
0 - 99
EC/CAS
7440-59-7
Name of the chemical
Helium He
Concentration
0 - 99
EC/CAS
7439-90-9
Name of the chemical
Krypton Kr
Concentration
0 - 99
EC/CAS
7727-37-9
Name of the chemical
Nitrogen N2
Concentration
0 - 99
EC/CAS
7440-63-3
Name of the chemical
Xenon Xe
Concentration
0 - 99
General Information
Version
1.4
Revision date
2022-02-23
Product name
HYDROGEN BROMIDE (<10%) in ARGON, HELIUM, KRYPTON, NEON, NITROGEN or XENON
1.2.1 Relevant identified uses
Industrial and professional use Lighting gas applications
Emergency telephone
1-800-645-4633, 1-800-424-9300, 001-703-527-3887
Icons in SDS
Company Information
company name
Linde Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H280, H314, H318, H332
Hazard statements
Code
Statements
H280
Contains gas under pressure; may explode if heated
Section 2
SECTION 2: Hazards identification
Classification of the substance or mixture GHS-US classification Press. Gas (Comp.) H280 Acute Tox. 4 (Inhalation:gas) H332 Skin Corr. 1A H314 Eye Dam. 1 H318
2.2 Label elements
GHS US labelling
Hazard pictograms
GHS04 GHS05
Signal word
Danger
Hazard statements
H280 - CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED H314 - CAUSES SEVERE SKIN BURNS AND EYE DAMAGE H332 - HARMFUL IF INHALED CGA-HG22 - CORROSIVE TO THE RESPIRATORY TRACT.
Precautionary statements
P202 - Do not handle until all safety precautions have been read and understood. P260 - Do not breathe gas/vapours P262 - Do not get in eyes, on skin, or on clothing. P264 - Wash exposed skin thoroughly after handling CGA-PG18 - When returning cylinder, install leak tight valve outlet cap or plug. P301+P330+P331 - IF SWALLOWED: Rinse mouth. Do NOT induce vomiting P310 - Immediately call a POISON CENTER/doctor. P303, P361, P353, P363, P310 - IF ON SKIN OR (HAIR): Take off immediately all contaminated clothing. Rinse skin with water/shower. Wash contaminated clothing before EN (English) SDS ID: LIND-M0100 1/12 reuse. Immediately call a POISON CENTER/doctor. P304, P340, P310 - IF INHALED: Remove person to fresh air and keep comfortable for breathing.Immediately call a POISON CENTER/doctor. P305, P351, P338, P310 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/doctor. P363 - Wash contaminated clothing before reuse. P405 - Store locked up. P501 - Dispose of contents/container in accordance with container Supplier/owner instructions P271+P403 - Use and store only outdoors or in a well-ventilated place. CGA-PG12 - Do not open valve until connected to equipment prepared for use. CGA-PG06 - Close valve after each use and when empty. CGA-PG05 - Use a back flow preventive device in the piping. CGA-PG20+CGA-PG10 - Use only with equipment of compatible materials of construction and rated for cylinder pressure. CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F). P280+P284 - Wear protective gloves, protective clothing, eye protection, respiratory protection, and/or face protection.
Other hazards which do not result in classification
Asphyxiant in high concentrations.
Ingredient(s) with unknown acute toxicity
Not applicable
2.1 Classification of the substance or mixture
GHS-US classification Press. Gas (Comp.) H280 Acute Tox. 4 (Inhalation:gas) H332 Skin Corr. 1A H314 Eye Dam. 1 H318