Note: Ingredients listed on restricted chemical lists
EC/CAS
7440-63-3
Name of the chemical
Xenon Xe
Concentration
≤99
EC/CAS
7727-37-9
Name of the chemical
Nitrogen N2
Concentration
≤99
EC/CAS
7439-90-9
Name of the chemical
Krypton Kr
Concentration
≤99
EC/CAS
7440-59-7
Name of the chemical
Helium He
Concentration
≤99
EC/CAS
7440-37-1
Name of the chemical
Argon Ar
Concentration
≤99
General Information
Version
1.4
Revision date
2022-02-23
Product name
BROMODICHLOROMETHANE (<1%) in ARGON, HELIUM, KRYPTON, NEON, NITROGEN or XENON
1.2.1 Relevant identified uses
Industrial and professional use Lighting gas applications
Emergency telephone
1-800-645-4633, 1-800-424-9300, 001-703-527-3887
Icons in SDS
Company Information
company name
Linde Inc
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H280, H351
Hazard statements
Code
Statements
H280
Contains gas under pressure; may explode if heated
Section 2
SECTION 2: Hazards identification
Classification of the substance or mixture GHS-US classification Simple asphyxiant SIAS Press. Gas (Comp.) H280 Carc. 2 H351
2.2 Label elements
GHS US labelling
Hazard pictograms
GHS04 GHS08
Signal word
Warning
Hazard statements
H280 - CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED H351 - SUSPECTED OF CAUSING CANCER. OSHA-H01 - MAY DISPLACE OXYGEN AND CAUSE RAPID SUFFOCATION
Precautionary statements
P201 - Obtain special instructions before use. P202 - Do not handle until all safety precautions have been read and understood. P280 - Wear protective gloves/protective clothing/eye protection/face protection. P405 - Store locked up. P501 - Dispose of contents/container in accordance with container Supplier/owner instructions P271+P403 - Use and store only outdoors or in a well-ventilated place. CGA-PG05 - Use a back flow preventive device in the piping. CGA-PG10 - Use only with equipment rated for cylinder pressure. CGA-PG12 - Do not open valve until connected to equipment prepared for use. CGA-PG06 - Close valve after each use and when empty. CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F). EN (English) SDS ID: LIND-M0020 1/11 P304, P340, P313 - IF INHALED: Remove person to fresh air and keep comfortable for breathing. Get medical advice/attention.
Other hazards which do not result in classification
Asphyxiant in high concentrations.
Ingredient(s) with unknown acute toxicity
Not applicable
2.1 Classification of the substance or mixture
GHS-US classification Simple asphyxiant SIAS Press. Gas (Comp.) H280 Carc. 2 H351