General Information
Version
1.3
Revision date
2024-04-23
Product name
Ammonia-15N
Substance name
Ammonia-15N
CAS No.
13767-16-3
1.2.1 Relevant identified uses
Industrial use; Use as directed
Emergency telephone
1-800-645-4633, 1-800-424-9300, 001-703-527-3887
Icons in SDS
Company Information
company name
Linde Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H221, H280, H314, H332, H335, H400
Hazard statements
Code
Statements
H221
Flammable gas
Section 2
SECTION 2: Hazards identification
Classification of the substance or mixture GHS-US classification Flam. Gas 2 H221 Press. Gas (Liq.) H280 Acute Tox. 4 (Inhalation:gas) H332 Skin Corr. 1B H314 STOT SE 3 H335 Aquatic Acute 1 H400
2.2 Label elements
GHS US labelling
Hazard pictograms
GHS04 GHS05 GHS09
Signal word
Danger
Hazard statements
H221 - FLAMMABLE GAS H280 - CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED H314 - CAUSES SEVERE SKIN BURNS AND EYE DAMAGE CGA-HG22 - CORROSIVE TO THE RESPIRATORY TRACT. H332 - HARMFUL IF INHALED CGA-HG01 - MAY CAUSE FROSTBITE. H400 - VERY TOXIC TO AQUATIC LIFE
Precautionary statements
P202 - Do not handle until all safety precautions have been read and understood. P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P260 - Do not breathe gas EN (English) SDS ID: LIND-P165 1/11 P262 - Do not get in eyes, on skin, or on clothing. P271+P403 - Use and store only outdoors or in a well-ventilated place. P273 - Avoid release to the environment. P391 - Collect spillage. P280+P284 - Wear protective gloves, protective clothing, eye protection, respiratory protection, and/or face protection. P377 - LEAKING GAS FIRE: Do not extinguish, unless leak can be stopped safely. P381 - Eliminate all ignition sources if safe to do so. P501 - Dispose of contents/container in accordance with container supplier/owner instructions CGA-PG05 - Use a back flow preventive device in the piping. CGA-PG20+CGA-PG10 - Use only with equipment of compatible materials of construction and rated for cylinder pressure. CGA-PG12 - Do not open valve until connected to equipment prepared for use. CGA-PG06 - Close valve after each use and when empty. CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F). P304-P340-P312 - IF INHALED: remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a POISON CENTER/doctor if you feel unwell. P305+P351+P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Contact an ophthalmologist immediately. P303+P361+P353 - IF ON SKIN OR (HAIR): Take off immediately all contaminated clothing. Rinse skin with water/shower. P363 - Wash contaminated clothing before reuse. P336 - Thaw frosted parts with lukewarm water. Do not rub affected area. P310 - Immediately call a POISON CENTER/doctor. P332+P313 - IF SKIN IRRITATION OCCURS: Get medical advice/attention.
Other hazards which do not result in classification
Contact with liquid may cause cold burns/frostbite.
Ingredient(s) with unknown acute toxicity
Not applicable
2.1 Classification of the substance or mixture
GHS-US classification Flam. Gas 2 H221 Press. Gas (Liq.) H280 Acute Tox. 4 (Inhalation:gas) H332 Skin Corr. 1B H314 STOT SE 3 H335 Aquatic Acute 1 H400