Note: Ingredients listed on restricted chemical lists
EC/CAS
7440-59-7
Name of the chemical
Helium He
Concentration
90
EC/CAS
7664-41-7
Name of the chemical
ammonia
Concentration
10
General Information
Version
2.1
Revision date
2022-02-23
Product name
Ammonia (10%) BALANCE HELIUM
1.2.1 Relevant identified uses
Industrial and professional use
Emergency telephone
1-800-645-4633, 1-800-424-9300, 001-703-527-3887
Icons in SDS
Company Information
company name
Linde Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H280, H314, H318, H401
Hazard statements
Code
Statements
H280
Contains gas under pressure; may explode if heated
Section 2
SECTION 2: Hazards identification
Classification of the substance or mixture GHS-US classification Simple asphyxiant SIAS Press. Gas (Comp.) H280 Skin Corr. 1B H314 Eye Dam. 1 H318 Aquatic Acute 2 H401
2.2 Label elements
GHS US labelling
Hazard pictograms
GHS04 GHS05
Signal word
Danger
Hazard statements
H280 - CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED H314 - CAUSES SEVERE SKIN BURNS AND EYE DAMAGE H318 - CAUSES SERIOUS EYE DAMAGE. H401 - TOXIC TO AQUATIC LIFE OSHA-H01 - MAY DISPLACE OXYGEN AND CAUSE RAPID SUFFOCATION.
Precautionary statements
P202 - Do not handle until all safety precautions have been read and understood. P260 - Do not breathe gas P264 - Wash clothing, hands, forearms and face thoroughly after handling P273 - Avoid release to the environment. P280 - Wear eye protection, face protection, protective clothing, protective gloves, face shield. P303+P361+P353 - IF ON SKIN OR (HAIR): Take off immediately all contaminated clothing. Rinse skin with water/shower. P304, P340, P313 - IF INHALED: Remove person to fresh air and keep comfortable for breathing. Get medical advice/attention. EN (English) SDS ID: LIND-M0001H 1/10 P305+P351+P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P310 - Immediately call a POISON CENTER/doctor. P363 - Wash contaminated clothing before reuse. P405 - Store locked up. P501 - Dispose of contents/container in accordance with container Supplier/owner instructions P271+P403 - Use and store only outdoors or in a well-ventilated place. CGA-PG05 - Use a back flow preventive device in the piping. CGA-PG10 - Use only with equipment rated for cylinder pressure. CGA-PG12 - Do not open valve until connected to equipment prepared for use. CGA-PG06 - Close valve after each use and when empty. CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F).
Other hazards which do not result in classification
Asphyxiant in high concentrations.
Ingredient(s) with unknown acute toxicity
Not applicable
2.1 Classification of the substance or mixture