Note: Ingredients listed on restricted chemical lists
EC/CAS
7727-37-9
Name of the chemical
Nitrogen N2
Concentration
2.01
EC/CAS
124-38-9
Name of the chemical
Carbon dioxide CO2
Concentration
0.5
EC/CAS
7440-37-1
Name of the chemical
Argon Ar
Concentration
0.302
EC/CAS
630-08-0
Name of the chemical
Kohlenmonoxid
Concentration
0.1
General Information
Version
1.1
Revision date
2022-02-23
Product name
6 COMP MIXTURE METHANE BALANCE
1.2.1 Relevant identified uses
Industrial use; Use as directed
Emergency telephone
1-800-645-4633, 1-800-424-9300, 001-703-527-3887
Icons in SDS
Company Information
company name
Linde Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H220, H280, H360, H402
Hazard statements
Code
Statements
H220
Extremely flammable gas
Section 2
SECTION 2: Hazards identification
GHS US classification Classification of the substance or mixture GHS-US classification Flam. Gas 1 H220 Press. Gas (Comp.) H280 Repr. 1A H360 Aquatic Acute 3 H402
2.2 Label elements
GHS US labelling
Hazard pictograms
GHS02 GHS04 GHS08
Signal word
Danger
Hazard statements
H220 - EXTREMELY FLAMMABLE GAS H280 - CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED H360 - MAY DAMAGE FERTILITY OR THE UNBORN CHILD H402 - HARMFUL TO AQUATIC LIFE
Precautionary statements
P201 - Obtain special instructions before use. P202 - Do not handle until all safety precautions have been read and understood. P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P273 - Avoid release to the environment. P280 - Wear protective gloves/protective clothing/eye protection/face protection. P308+P313 - If exposed or concerned: Get medical advice/attention. P377 - LEAKING GAS FIRE: Do not extinguish, unless leak can be stopped safely. P381 - Eliminate all ignition sources if safe to do so. P405 - Store locked up. P501 - Dispose of contents/container in accordance with container Supplier/owner instructions P271+P403 - Use and store only outdoors or in a well-ventilated place. CGA-PG05 - Use a back flow preventive device in the piping. EN (English) SDS ID: LIND-CM00284 1/12 CGA-PG10 - Use only with equipment rated for cylinder pressure. CGA-PG12 - Do not open valve until connected to equipment prepared for use. CGA-PG06 - Close valve after each use and when empty. CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F). P304, P340, P313 - IF INHALED: Remove person to fresh air and keep comfortable for breathing. Get medical advice/attention.
Other hazards which do not result in classification
Asphyxiant in high concentrations.
Ingredient(s) with unknown acute toxicity
Not applicable
2.1 Classification of the substance or mixture
GHS-US classification Flam. Gas 1 H220 Press. Gas (Comp.) H280 Repr. 1A H360 Aquatic Acute 3 H402