Note: Ingredients listed on restricted chemical lists
EC/CAS
7727-37-9
Name of the chemical
Nitrogen N2
Concentration
0.00001 - 3
EC/CAS
124-38-9
Name of the chemical
Carbon dioxide CO2
Concentration
0.00001 - 1.2
EC/CAS
106-97-8
Name of the chemical
n-Butan, enthält 0,1% Butadien
Concentration
0.00001 - 1
EC/CAS
75-28-5
Name of the chemical
iso-Butan, enthält 0,1% Butadien
Concentration
0.00001 - 1
EC/CAS
110-54-3
Name of the chemical
n-Hexan (790/2009)
Concentration
0.00001 – 0.99999
General Information
Version
1.3
Revision date
2025-08-22
Product name
11 COMP METHANE BAL
1.2.1 Relevant identified uses
Industrial use; Use as directed
Emergency telephone
1-800-645-4633, 1-800-424-9300, 001-703-527-3887
Icons in SDS
Company Information
company name
Linde Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H220, H280, H361, H402, H412
Hazard statements
Code
Statements
H220
Extremely flammable gas
Section 2
SECTION 2: Hazards identification
Classification of the substance or mixture GHS-US classification Flam. Gas 1A H220 Press. Gas (Comp.) H280 Repr. 2 H361 Aquatic Acute 3 H402 Aquatic Chronic 3 H412
2.2 Label elements
GHS US labelling
Hazard pictograms
GHS02 GHS04 GHS08
Signal word
Danger
Hazard statements
H220 - EXTREMELY FLAMMABLE GAS H280 - CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED H361 - Suspected of damaging fertility or the unborn child. H402 - Harmful to aquatic life H412 - Harmful to aquatic life with long lasting effects CGA-HG04 - MAY FORM EXPLOSIVE MIXTURES WITH AIR
Precautionary statements
P201 - Obtain special instructions before use. P202 - Do not handle until all safety precautions have been read and understood. P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P271+P403 - Use and store only outdoors or in a well-ventilated place P273 - Avoid release to the environment. P280 - Wear protective gloves, protective clothing, eye protection, face protection, and hearing EN (English) SDS ID: LIND-CM00249 1/16 protection. P377 - LEAKING GAS FIRE: Do not extinguish, unless leak can be stopped safely. P381 - In case of leakage, eliminate all ignition sources. P405 - Store locked up. P501 - Dispose of contents and/or container to hazardous or special waste collection point, in accordance with local, regional, national and/or international regulations. P304, P340, P313 - IF INHALED: Remove person to fresh air and keep comfortable for breathing. Get medical advice/attention. P308+P313 - IF EXPOSED OR CONCERNED: Get medical advice/attention. CGA-PG05 - Use a back flow preventive device in the piping. CGA-PG10 - Use only with equipment rated for cylinder pressure. CGA-PG12 - Do not open valve until connected to equipment prepared for use. CGA-PG06 - Close valve after each use and when empty. CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F).
2.3 Other hazards
No additional information available
Ingredient(s) with unknown acute toxicity
Not applicable
2.1 Classification of the substance or mixture
GHS-US classification Flam. Gas 1A H220 Press. Gas (Comp.) H280 Repr. 2 H361 Aquatic Acute 3 H402 Aquatic Chronic 3 H412