General Information
Version
1.1
Revision date
2015-04-21
Product name
O2 in Minican
Product name
O2 in Minican
Identification on the label/Trade name
Sauerstoff 2.5, 4.5
CAS No.
7782-44-7
1.2.1 Relevant identified uses
Industrial and professional use for chemical analysis, calibration, (routine) quality control, laboratory use. Under controlled conditions
1.2.2. Uses advised against
Contact supplier for more information on uses. Uses other than those listed above are not supported
supplier name
Linde GmbH (LLC), Division Gas
Emergency telephone
+44 1865 407333, +49 89 220 61012
Icons in SDS
Company Information
company name
Linde GmbH (LLC), Division Gas
e-mail address of the competent person responsible for the Safety Data Sheet
Info@de.linde-gas.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H229, H270
Hazard statements
Code
Statements
H229
Pressurized container: may burst if heated
Section 2
SECTION 2: Hazards identification
Classification according to Regulation (EC) No 1272/2008 as amended Classification of the substance or mixture
Signal word
Danger
Hazard statements
H270: May cause or intensify fire; oxidizer. H229 Pressurized container May burst if heated
Precautionary statements
None.
Prevention
P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P211: Do not spray on an open flame or other ignition source. P220: Keep away from clothing and other combustible materials. P244: Keep valves and fittings free from oil and grease. P251: Do not pierce or burn, even after use.
Response
P102: Keep out of reach of children. P377 Leaking gas fire Do not extinguish, unless leak can be stopped safely. P381: In case of leakage, eliminate all ignition sources.
Storage
P410+P412: Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122°F. P403: Store in a well-ventilated place.
Disposal
P501: Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal. P502: Refer to manufacturer or supplier for information on recovery or recycling.
2.3 Other hazards
None.
2.1 Classification of the substance or mixture
Classification according to Regulation (EC) No 1272/2008 as amended. Physical Hazards Oxidizing gases Category 1 H270: May cause or intensify fire; oxidizer. Gases under pressure Compressed H229: Pressurized container: May burst if heated. gas