Note: Ingredients listed on restricted chemical lists
EC/CAS
200-839-4/75-10-5
Name of the chemical
Difluoromethane
Concentration
21,8867%
EC/CAS
468-710-7/754-12-1
Name of the chemical
2,3,3,3-Tetrafluoropropene
Concentration
3,3- 27,2296%
EC/CAS
206-557-8/354-33-6
Name of the chemical
Ethane, pentafluoro
Concentration
50,8837%
General Information
Version
1.0
Revision date
2014-08-28
Product name
CH2F2 21,8867 %;C3H2F4 27,2296 %;C2HF5 50,8837 %
Product name
CH2F2 21,8867 %;C3H2F4 27,2296 %;C2HF5 50,8837 %
Identification on the label/Trade name
Opteon XP44, R452A
Product Synonyms
R-452A, HFC-125 59 (w/w) %; HFC-1234yf 30 (w/w) %; HFC-32 11 (w/w) %
1.2.1 Relevant identified uses
Industrial and professional. Perform risk assessment prior to use Refrigerant
1.2.2. Uses advised against
Consumer use
supplier name
Linde Gas GmbH
Emergency telephone
43 50 4273, +43 1 406 43 43
Icons in SDS
Company Information
company name
Linde Gas GmbH
e-mail address of the competent person responsible for the Safety Data Sheet
office@at.linde-gas.com
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H280
Hazard statements
Code
Statements
H280
Contains gas under pressure; may explode if heated
Section 2
SECTION 2: Hazards identification
Classification according to Regulation (EC) No 1272/2008 as amended Classification of the substance or mixture
Signal word
Warning
Hazard statements
H280: Contains gas under pressure; may explode if heated.
Prevention
None.
Response
None.
Storage
P403: Store in a well-ventilated place.
Disposal
None.
Supplemental label elements
EIGA-0783 Contains fluorinated greenhouse gases EIGA-As Asphyxiant in high concentrations
2.3 Other hazards
Contact with evaporating liquid may cause frostbite or freezing of skin.
2.1 Classification of the substance or mixture
Classification according to Regulation (EC) No 1272/2008 as amended. Physical Hazards Gases under pressure Liquefied gas H280: Contains gas under pressure; may explode if heated.