Note: Ingredients listed on restricted chemical lists
EC/CAS
235-186-4/12125-02-9
Name of the chemical
Ammonium chloride
Concentration
1-<5%
General Information
Version
3.1
Revision date
2025-10-07
Product name
Paste Flux
1.2.1 Relevant identified uses
Metal Soldering
1.2.2. Uses advised against
Not known. Read this SDS before using this product
Emergency telephone
+1 (888) 609-1762, +1 (216) 383-8962, +1 (216) 383-8966, +1 (216) 383-8969, +359 2 9154 233, +39 055 794 7819, +371 67042473, +420 224 919 293, +370 (5) 2362052, +49 (0) 89 19240, 31(0)30 274 8888, +45 8212 1212, 22 59 13 00, +34 91 562 04 20, +48 12 411 99 99, 0800 147 111, +351 800 250 250, +33 1 45 42 59 59, +40 21 599 2300, 0344 892 0111, (0030) 2107793777, +3851 2348 342, +421 2 5477 4166, +36-80-201-199
Icons in SDS
Company Information
company name
Lincoln Electric Europe B.V
e-mail address of the competent person responsible for the Safety Data Sheet
SDS@lincolnelectric.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H302, H314, H318, H335, H350, H400, H410
Hazard statements
Code
Statements
H302
Harmful if swallowed
Section 2
SECTION 2: Hazards identification
Classification according to Regulation (EC) No 1272/2008 as amended Classification of the substance or mixture The product has been classified according to the legislation in force
Health hazards
Acute toxicity (Oral) Skin corrosion Serious eye damage Category 4 H302 Category 1 H314 Category 1 H318 Carcinogenicity Category 1B H350 Specific Target Organ Toxicity - Category 3 H335 Single Exposure Environmental Hazards Acute hazards to the aquatic Category 1 H400
Environmental hazards
Chronic hazards to the aquatic Category 1 H410
Contains
Petrolatum Zinc chloride
Signal word
Danger
Hazard statements
H302: Harmful if swallowed. H314: Causes severe skin burns and eye damage. H350: May cause cancer. H335: May cause respiratory irritation. H410: Very toxic to aquatic life with long lasting effects.
Prevention
P201: Obtain special instructions before use. P202: Do not handle until all safety precautions have been read and understood. P260: Do not breathe dust/fume/gas/mist/vapors/spray. P264: Wash face, hands and any exposed skin thoroughly after handling. P273: Avoid release to the environment. P280: Wear protective gloves/ protective clothing/ eye protection/ face protection.
Response
P301+P330+P331 IF SWALLOWED Rinse mouth. Do NOT induce vomiting. P310: Immediately call a POISON CENTER or doctor/ physician. P303+P361+P353 IF ON SKIN (or hair) Take off immediately all contaminated clothing. Rinse skin with water [or shower]. P312: Call a POISON CENTER or doctor/ physician if you feel unwell. P305+P351+P338 IF IN EYES Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P308+P313 IF exposed or concerned Get medical advice/attention P391: Collect spillage.
2.3 Other hazards
Overexposure to fumes and gases from the solder and/or flux material can be hazardous. Read and understand the manufacturer’s instructions, Safety Data Sheets and the precautionary labels before using this product. Substance(s) formed under the conditions of use Fumes produced from use of this product may contain the following constituent(s) and/or their complex metallic oxides as well as solid particles or other constituents from the solder, brazing consumable, flux material or base metal, or base metal coating not listed below. Chemical name Carbon dioxide Carbon monoxide Nitrogen dioxide Ozone CAS-No. 124-38-9 630-08-0 10102-44-0 10028-15-6
2.1 Classification of the substance or mixture
The product has been classified according to the legislation in force. Classification according to Regulation (EC) No 1272/2008 as amended. Health Hazards Acute toxicity (Oral) Category 4 H302 Skin corrosion Category 1 H314 Serious eye damage Category 1 H318 Carcinogenicity Category 1B H350 Specific Target Organ Toxicity - Category 3 H335 Single Exposure Environmental Hazards Acute hazards to the aquatic Category 1 H400 environment Chronic hazards to the aquatic Category 1 H410 environment