General Information
Revision date
2017-05-02
Product name
Sodium persulfate, 98+%
Chemical name
Not Applicable
CAS No.
7775-27-1
REACH No
is
1.2.1 Relevant identified uses
Use as laboratory reagent, Scientific research and development
1.2.2. Uses advised against
Not for consumer use
Emergency telephone
1-800-424-9300, 703-527-3887, +1 703-741-5970, +(353)-19014670, +(44)-870-8200418
Icons in SDS
Company Information
company name
LIFE TECHNOLOGIES EUROPE BV
e-mail address of the competent person responsible for the Safety Data Sheet
MSDS@lifetech.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H272, H302, H315, H317, H319, H334, H335
Hazard statements
Code
Statements
H272
May intensify fire; oxidiser
Section 2
SECTION 2: Hazards identification
Physical hazards
Oxidising liquids Category 2
Health hazards
Acute oral toxicity Category 4 Skin corrosion/irritation Category 2 Serious eye damage/eye irritation Category 2 Respiratory sensitiser Category 1 Skin sensitiser Category 1 Specific target organ toxicity - Single exposure Category 3
Environmental hazards
Not Hazardous
Additional information
No information available
2.2 Label elements
Labelling
Signal word
Danger
Hazard statements
H272 - May intensify fire; oxidiser H302 - Harmful if swallowed H315 - Causes skin irritation H319 - Causes serious eye irritation H334 - May cause allergy or asthma symptoms or breathing difficulties if inhaled H317 - May cause an allergic skin reaction H335 - May cause respiratory irritation
Prevention
P280 - Wear protective gloves/protective clothing/eye protection/face protection P264 - Wash hands thoroughly after handling P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking P261 - Avoid breathing dust/fume/gas/mist/vapours/spray P220 - Keep/Store away from clothing/ combustible materials
Response
P370 + P378 - In case of fire: Use dry sand, dry chemical or alcohol-resistant foam for extinction P301 + P310 - IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician P302 + P352 - IF ON SKIN: Wash with plenty of soap and water P305 + P351 + P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing P304 + P340 - IF INHALED: Remove person to fresh air and keep comfortable for breathing
Storage
P403 + P233 - Store in a well-ventilated place. Keep container tightly closed
Disposal
P501 - Dispose of contents/ container to an approved waste disposal plant
2.3 Other hazards
Not Applicable