Note: Ingredients listed on restricted chemical lists
EC/CAS
204-617-8/123-31-9
Name of the chemical
1,4-Dihydroxybenzol (790/2009)
Concentration
0.1-1
General Information
Revision date
2018-02-14
Product name
SlowFade Diamond Antifade Mountant with DAPI
REACH No
is
1.2.2. Uses advised against
Not for consumer use
Emergency telephone
for Hazardous Materials Within the USA + Canada 1-800-424-9300 and +1
Icons in SDS
Company Information
company name
LIFE TECHNOLOGIES EUROPE BV
e-mail address of the competent person responsible for the Safety Data Sheet
MSDS@lifetech.com
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H317, H341, H351
Hazard statements
Code
Statements
H317
May cause an allergic skin reaction
Section 2
Physical hazards
Not Hazardous
Health hazards
Skin sensitiser Category 1 Germ cell mutagenicity Category 2 Carcinogenicity Category 2
Environmental hazards
Not Hazardous
Additional information
No information available
2.2 Label elements
Labelling according to Regulation (EC) No 1272/2008 [CLP]
Signal word
Warning
Hazard statements
H317 - May cause an allergic skin reaction H341 - Suspected of causing genetic defects H351 - Suspected of causing cancer
Prevention
P201 - Obtain special instructions before use P202 - Do not handle until all safety precautions have been read and understood P261 - Avoid breathing dust/fume/gas/mist/vapours/spray P272 - Contaminated work clothing should not be allowed out of the workplace P273 - Avoid release to the environment
Response
P302 + P352 - IF ON SKIN: Wash with plenty of soap and water P308 + P313 - IF exposed or concerned: Get medical advice/attention P333 + P313 - If skin irritation or rash occurs: Get medical advice/attention P362 + P364 - Take off contaminated clothing and wash it before reuse
Storage
Not Applicable
Disposal
P501 - Dispose of contents/ container to an approved waste disposal plant
2.3 Other hazards
Not Applicable