Note: Ingredients listed on restricted chemical lists
EC/CAS
98-56-6
Name of the chemical
4-Chloro-alpha,alpha,alpha-trifluorotoluene
Concentration
40-<60
EC/CAS
123-86-4
Name of the chemical
acetic acid, butyl ester
Concentration
5-<10 <1
General Information
Product name
ACTIVATOR
Manufacturer Name
Liberty Bell Equipment Corp
Emergency telephone
24 Hrs
Icons in SDS
Company Information
company name
Liberty Bell Equipment Corp
GHS Information
Signal word
Danger
Section 2
SECTION 2: Hazards identification
Physical hazards
Flammable liquids Category 2
Health hazards
Acute toxicity, inhalation Category 3 Sensitization, respiratory Category 1 Sensitization, skin Category 1
Environmental hazards
Not classified.
Signal word
Danger
Hazard statements
Highly flammable liquid and vapor. May cause an allergic skin reaction. Toxic if inhaled. May cause allergy or asthma symptoms or breathing difficulties if inhaled.
Prevention
Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Keep container tightly closed. Ground/bond container and receiving equipment. Use explosion-proof electrical/ventilating/lighting equipment. Use only non-sparking tools. Take precautionary measures against static discharge. Avoid breathing mist or vapor. Use only outdoors or in a well-ventilated area. Contaminated work clothing must not be allowed out of the workplace. Wear protective gloves/eye protection/face protection. In case of inadequate ventilation wear respiratory protection.
Response
If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. If inhaled: Remove person to fresh air and keep comfortable for breathing. Call a poison center/doctor. If skin irritation or rash occurs: Get medical advice/attention. If experiencing respiratory symptoms: Call a poison center/doctor. Wash contaminated clothing before reuse. In case of fire: Use appropriate media to extinguish.
Storage
Store in a well-ventilated place. Keep container tightly closed. Store in a well-ventilated place. Keep cool. Store locked up.
Disposal
Dispose of contents/container in accordance with local/regional/national/international regulations. Hazard(s) not otherwise Static accumulating flammable liquid can become electrostatically charged even in bonded and
Classified (HNOC)
grounded equipment. Sparks may ignite liquid and vapor. May cause flash fire or explosion.
Additional information
54% of the mixture consists of component(s) of unknown acute inhalation toxicity.