Note: Ingredients listed on restricted chemical lists
EC/CAS
276-736-3/72623-85-9
Name of the chemical
Lubricating oils (petroleum), C20-50, hydrotreated neutral oil-based, high-viscosity
Concentration
70-100%
EC/CAS
471-480-0/29118-24-9
Name of the chemical
(E)-1,3,3,3-Tetrafluoro-1-propene
Concentration
1-3%
EC/CAS
204-696-9/124-38-9
Name of the chemical
Carbon dioxide CO2
Concentration
1-3%
General Information
Revision date
2018-11-06
Product name
ACF-50 Aerosol
1.2.1 Relevant identified uses
ACF-50® is an industrial product designed to prevent and treat corrosion on non-ferrous and ferrous metals, protect electronic equipment, and to lubricate/penetrate mechanized parts
Manufacturer Name
Lear Chemical Research Corp
Emergency telephone
1 800-256-2548, 1 905-890-3466
Icons in SDS
Company Information
company name
Lear Chemical Research Corp
e-mail address of the competent person responsible for the Safety Data Sheet
info@learchem.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H229, H315, H319
Hazard statements
Code
Statements
H229
Pressurized container: may burst if heated
Section 2
SECTION 2: Hazards identification
OSHA Appearance Purple Health Acute Toxicity Oral-Eye-Dermal Category Physical State Mixture Odor Aromatic 5 Inhalation: Category 4
Hazard statements
H229 – Pressurized container: May burst if heated H315 – Causes skin irritation H319 – Causes serious eye irritation
Prevention
P102 – Keep away from children P210 – Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P280 – Wear protective gloves/protective clothing/eye protection/face protection
Response
P302+P352 – IF ON SKIN: Wash with plenty of water P362+P364 – Take off contaminated clothing and wash it before reuse P305+P351+P338 – IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do so. Continue rinsing. P337+P313 – If eye irritation persists: Get medical advice/attention
Storage
P410 + P412 – Protect from sunlight. Do not expose to temperatures exceeding 50°C / 122°F.
Precautionary statements
Disposal P251 – Do not pierce or burn, even after use
2.3 Other hazards
(HNOC)-Not Applicable