Note: Ingredients listed on restricted chemical lists
EC/CAS
108-88-3
Name of the chemical
Toluene
Concentration
N/A
EC/CAS
13463-67-7
Name of the chemical
Reaction mass of titanium dioxide and silver chloride
Concentration
N/A
EC/CAS
7631-86-9
Name of the chemical
Silver adsorbed on silicon dioxide
Concentration
N/A
General Information
Revision date
2010-08-16
Product name
Gotta Grip Clear
1.2.1 Relevant identified uses
Coating
supplier name
Drummond, A Lawson Brand
Icons in SDS
Company Information
company name
Lawson Products, Inc
Section 2
SECTION 2: Hazards identification
required. Artificial respiration and/or oxygen may be necessary. Emergency Overview Flammable. Irritant. 5. FIRE FIGHTING MEASURES
Medical Conditions Generally Aggravated by Exposure
Reports have associated prolonged overexposure to solvents with permanent brain and nervous system damage Flash point °C 7 Flash point °F 45 Method No information available
Principle Routes of Exposure
Eyes. Skin. Inhalation. Ingestion Autoignition temperature °C No data available Autoignition temperature °F No data available
Potential health effects
Eyes Severe irritation. Redness. Tearing. Blurred vision. Skin Repeated or prolonged exposure may cause . Skin Irritation. Defatting. Dermatitis. Allergic reaction . Inhalation Nasal irritation. Respiratory irritation. Extreme overexposure may cause. Upper respiratory tract irritation. Dizziness. Nausea. Central nervous system effects. Reports have associated repeated and prolonged occupational exposure to solvents with permanent brain damage. Central nervous system damage. Ingestion Ingestion may cause gastrointestinal irritation, nausea, vomiting and diarrhea. May cause chemical pneumonitis if aspirated into lungs Flammability Limits (% in Air) Upper No data available Lower No data available Suitable extinguishing media Foam. Carbon dioxide (CO2). Water fog. Dry chemical. Special protective equipment for firefighters As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear Fire and Explosion Hazards Extremely flammable. Water should be used to cool closed containers to prevent pressure build-up and possible autoignition or explosion when exposed to extreme heat . Vapors are heavier than air and may travel along the ground to an ignition source distant from material handling area. Possible ignition sources include pilot lights, flames, lighted cigarettes, heating elements, electric motors, sparks from electrical switches.