General Information
Revision date
2017-07-16
Product name
LEVELEX-ECO PLUS
Product Synonyms
None
1.2.1 Relevant identified uses
Mineral Dry Mortar for Coating or mixture and uses advised against
1.2.2. Uses advised against
Workers (and your customers or users in the case of resale) should be informed of the potential presence of respirable dust well as their potential hazards. Appropriate training in the proper use and handling of this material should be provided as required under applicable regulations
Emergency telephone
Centro Antiveleni Policlinico A. Gemelli – ROMA – Tel +39 06 3054343
Icons in SDS
Company Information
company name
LATICRETE EUROPE SRL
e-mail address of the competent person responsible for the Safety Data Sheet
info@laticreteeurope.com
GHS Information
Signal word
Void
Section 2
EU Classification
Regulation (EC) No 1272/2008 as amended The Product is not classified and labeled according to the CLP-regulation.
2.2 Label elements
Label according to Regulation : Void (EC) No. 1272/2008 as amended
Hazard pictograms
Void
Signal word
Void
Hazard statements
Void
Precautionary statements
P101 If medical advice is needed, have product container or label at hand. P102 Keep out of reach of children. P103 Read label before use. P261 Avoid breathing dust. P280 Wear protective gloves/protective clothing/eye protection/face protection Version #: 01 Revision Date: -16/07/2017 Issue date 17-JULY-2017 SDS UK 1 /10
Special Provisions
None
Contains
Mineral Binders
Annex XVII - Restrictions on the manufacture, placing on the market and use of certain dangerous substances, mixtures and articles
None
Prevention
Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Do not breathe dust/fume. Wash thoroughly after handling. Wear protective gloves/protective clothing/eye protection/face protection.
Response
If exposed or concerned Get medical advice/attention. If on skin Wash with plenty of water. If skin irritation or rash occurs: Get medical advice/attention.
Storage
Refer point 7.2
Disposal
Dispose of waste and residues in accordance with local authority requirements.
Supplemental label elements
Nil
2.3 Other hazards
Quartz (including Cristobalite and Trydimite) is known as a cause for silicosis in humans. The air threshold value for the respirable fraction is 0.15 mg/m³. Besides the air threshold value the general dust limit value has to be observed. The impact of quartz dust (including Cristobalite and Trydimite) is a long-term effect and depends on the dust dosage, which is determined by a long lasting average dust concentration (respirable fraction).
PBT Substances
Inapplicable.
vPvB Substances
Inapplicable