Note: Ingredients listed on restricted chemical lists
EC/CAS
14808-60-7
Name of the chemical
Silica, crystalline
Concentration
N/A
General Information
Revision date
2007-08-14
Product name
SUEDE CH
Chemical name
Pigmented Portland Cement/Silica Mixture
1.2.1 Relevant identified uses
Pigmented Portland Cement/Silica Mixture
Emergency telephone
Regulatory Affairs
Icons in SDS
Company Information
company name
LANXESS Corporation
GHS Information
Signal word
WARNING!
Section 2
SECTION 2: Hazards identification
Emergency Overview WARNING! Color Beige Form solid Powder Odor Odorless Causes respiratory tract irritation. Causes skin irritation. Causes eye irritation. May cause lung damage. Contains material which can cause cancer.
Principle Routes of Exposure
Inhalation, Skin Contact, Eye Contact, Ingestion
Medical Conditions Generally Aggravated by Exposure
Respiratory disorders, Eye disorders, Skin disorders Exposure: HUMAN EFFECTS AND SYMPTOMS OF OVEREXPOSURE Inhalation Acute Inhalation For Product: SUEDE CH Causes respiratory tract irritation with symptoms of coughing, sore throat and runny nose. For Component: Crystalline Quartz Silica May be harmful by inhalation. May cause mechanical irritation. For Component: Iron (III) Oxide May cause mechanical irritation. For Component: Calcium sulfate Causes respiratory tract irritation with symptoms of coughing, sore throat and runny nose. Skin Acute Skin For Product: SUEDE CH Causes irritation with symptoms of reddening, itching, and swelling. Not expected to be a skin sensitizer. For Component: Crystalline Quartz Silica May cause mechanical irritation. For Component: Portland Cement Corrosive with symptoms of reddening, itching, swelling, burning and possible permanent damage. Not expected to be a skin sensitizer. For Component: Iron (III) Oxide May cause mechanical irritation. For Component: Calcium sulfate May cause irritation with symptoms of reddening and itching. For Component: Titanium dioxide (Rutile) Not expected to be irritating. Chronic Skin For Product: SUEDE CH Prolonged or repeated skin contact may cause dermatitis with symptoms of red, itchy, dry skin. Eye Acute Eye For Product: SUEDE CH Causes irritation with symptoms of reddening, tearing, stinging, and swelling. For Component: Crystalline Quartz Silica May cause mechanical irritation. For Component: Portland Cement Causes irritation with symptoms of reddening, tearing, stinging, and swelling. For Component: Iron (III) Oxide May cause mechanical irritation. For Component: Calcium sulfate May cause irritation with symptoms of reddening, tearing and stinging. For Component: Titanium dioxide (Rutile) Not expected to be irritating. Ingestion Acute Ingestion For Product: SUEDE CH Not expected to be harmful if swallowed. For Component: Crystalline Quartz Silica Not expected to be harmful if swallowed. For Component: Calcium sulfate Symptoms of ingestion may include abdominal pain, nausea, vomiting, and diarrhea. Not expected to be harmful if swallowed. For Component: Titanium dioxide (Rutile) Not expected to be harmful if swallowed. General Effects of Exposure Acute Effects of Exposure For Product: SUEDE CH Exposure to Silica, Quartz can cause a very serious lung disease called Silicosis with cough, shortness of breath, and changes in chest x-ray. The earliest symptoms of silicosis may include: Shortness of breath, coughing, wheezing, fatigue, chest pain, loss of appetite and fever. For Component: Crystalline Quartz Silica Exposure to Silica, Quartz can cause a very serious lung disease called Silicosis with cough, shortness of breath, and changes in chest x-ray. The earliest symptoms of silicosis may include: Shortness of breath, coughing, wheezing, fatigue, chest pain, loss of appetite and fever.
Potential chronic health
of Exposure For Product: SUEDE CH Excessive exposure to airborne crystalline silica can cause fibrotic lung damage, with scarring of the lungs with cough and shortness of breath. This is called "Silicosis". This is generally a slowly developing fibrotic disease as symptoms are usually delayed for 10 years or more. Symptoms are dyspnea, chest pain, breathlessness, and cough. The chronic lung scarring developed from the silica dust causes a progressive massive fibrosis. This may lead to increased susceptibility to tuberculosis. For Component: Crystalline Quartz Silica Excessive exposure to airborne crystalline silica can cause fibrotic lung damage, with scarring of the lungs with cough and shortness of breath. This is called "Silicosis". This is generally a slowly developing fibrotic disease as symptoms are usually delayed for 10 years or more. Symptoms are dyspnea, chest pain, breathlessness, and cough. The chronic lung scarring developed from the silica dust causes a progressive massive fibrosis. This may lead to increased susceptibility to tuberculosis. Other Effects of Exposure For Product: SUEDE CH Prolonged inhalation (6 to 10 years) of iron oxide fume has been reported to produce changes in lung x- rays of exposed individuals. This condition, siderosis, is considered to be a begnign pnuemoconiosis that exhibits no adverse health effects. Siderosis has been observed among occupations such as arc-welders where iron oxide fumes are present. To the best of our knowledge, this condition has not been observed after prolonged exposure to iron oxide pigments. For Component: Iron (III) Oxide Prolonged inhalation (6 to 10 years) of iron oxide fume has been reported to produce changes in lung x- rays of exposed individuals. This condition, siderosis, is considered to be a begnign pnuemoconiosis that exhibits no adverse health effects. Siderosis has been observed among occupations such as arc-welders where iron oxide fumes are present. To the best of our knowledge, this condition has not been observed after prolonged exposure to iron oxide pigments. Carcinogenic Effects For Component: Titanium dioxide (Rutile) Human epidemiology studies do not suggest an association between occupational exposure to titanium dioxide and risk of cancer. Carcinogenicity: Crystalline Quartz Silica NTP - Hazard Designation: Known carcinogen. IARC - Overall evaluation: 1 Human carcinogen. Titanium dioxide (Rutile) IARC - Overall evaluation: 2B Possible carcinogen.