Note: Ingredients listed on restricted chemical lists
EC/CAS
7440-44-0
Name of the chemical
Carbon black
Concentration
≥80
EC/CAS
215-108-5/1302-78-9
Name of the chemical
bentonite
Concentration
≤20
EC/CAS
238-455-4/14464-46-1
Name of the chemical
Cristobalit (s. u. TRGS 906)
Concentration
1 %
EC/CAS
238-878-4/14808-60-7
Name of the chemical
Silica, crystalline
Concentration
N/A
General Information
Version
1.2
Revision date
2025-10-16
Product name
CHARBON SUPER ULTOSE GR
1.2.1 Relevant identified uses
Professional use Industrial/Professional use spec
Manufacturer Name
LAMOTHE-ABIET
Icons in SDS
Company Information
company name
LAMOTHE-ABIET
e-mail address of the competent person responsible for the Safety Data Sheet
contact@lamothe-abiet.com
Section 2
SECTION 2: Hazards identification
According to Regulation (EC) No. 1272/2008 (CLP) Classification of the substance or mixture
Other hazards which do not result in classification
Activated carbon (especially when wet) can deplete oxygen from air in enclosed spaces, and dangerously low levels of oxygen may result. Prior to entering a confined space that contains or previously contained activated carbon, the space should be evaluated for oxygen and carbon monoxide concentrations, and any other hazards, by a qualified person. Avoid dust formation. Powdered material may form an explosible dust-air mixture. If transferring product under pressure, avoid generation of dust if an ignition source is present. Activated carbons have high surface area which may cause self-heating during oxidation. See Section 5. This product contains less than 1 % crystalline silica (fine fraction) consisting of cristobalite (fine fraction) and quartz (fine fraction). Cristobalite CAS-No. 14464-46-1 EC No. 238-455-4 Quartz CAS-No. 14808-60-7 EC No. 238-878-4. Do not generate dust because airborne respirable crystalline silica may be generated. Dust of the product, if present, may cause respiratory irritation after excessive inhalation exposure.
2.1 Classification of the substance or mixture
Classification according to Regulation (EC) No. 1272/2008 [CLP] Not classified Adverse physicochemical, human health and environmental effects This product does not meet the criteria for classification as hazardous as defined in the Regulation EC 1272/2008. Depending on the type of handling and use (e.g. grinding, drying), airborne respirable crystalline silica may be generated. Prolonged and/or massive inhalation of respirable crystalline silica dust may cause lung fibrosis, commonly referred to as silicosis. Principal symptoms of silicosis are cough and breathlessness. Occupational exposure to respirable crystalline silica dust should be monitored and controlled.