General Information
Revision date
2015-10-26
Product name
- DIBK(Diisobutyl Ketone)
CAS No.
108-83-8
Emergency telephone
+82-61-688-3682
Icons in SDS
Company Information
company name
KUMHO P&B CHEMICALS. INC
e-mail address of the competent person responsible for the Safety Data Sheet
solvent_domestic@kpb.co.kr
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H226, H305, H331, H335
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
Section 2
2.1 Classification of the substance or mixture
Flammable liquids : Category3 Acute toxicity (inhalation vapor) Category3 - Specific target organ toxicity(Single exposure) : Category3(Respiratory tract irritation)
Aspiration hazard
Category2
Signal word
Danger
Hazard statements
H226 Flammable liquid and vapour - H305 May be harmful if swallowed and enters airways - H331 Toxic if inhaled - H335 May cause respiratory irritation.
Prevention
P210 Keep away from heat/sparks/open flames/hot surfaces. ? No smoking. - P233 Keep container tightly closed. - P240 Ground/bond container and receiving equipment. - P241 Use explosion-proof electrical/ventilating/lighting/equipment. - P242 Use only non-sparking tools. Flammable liquids (chapter 2.6) 1, 2, 3 - P243 Take precautionary measures against static discharge. - P261 Avoid breathing dust/fume/gas/mist/vapours/spray. - P271 Use only outdoors or in a well-ventilated area. - P280 Wear protective gloves/protective clothing/eye protection/face protection.
Response
P301+P310 IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician. - P303+P361+P353 IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower. - P304+P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. - P311 Call a POISON CENTER or doctor/physician. - P312 Call a POISON CENTER or doctor/physician if you feel unwell. - P321 Specific treatment - P331 Do NOT induce vomiting. - P370+P378 In case of fire: Use Suitable extinguishing media for extinction(Refer Section MSDS 5).
Storage
P403+P233 Store in a well-ventilated place. Keep container tightly closed. - P403+P235 Store in a well-ventilated place. Keep cool. - P405 Store locked up.
Disposal
P501 Dispose of contents/container in accordance with local/regional/national/international regulation
Other hazards which do not result in classification
NFPA Classification) ○ NFPA grade (0 ~ 4 level) Health 1 , Flammability 2, Reactivity 0