Note: Ingredients listed on restricted chemical lists
EC/CAS
212-782-2/868-77-9
Name of the chemical
2-hydroxyethyl methacrylate
Concentration
75-90%
General Information
Version
7 (replaces version 6
Revision date
2022-05-03
Product name
Technovit 7100 liquid
1.2.1 Relevant identified uses
Resin for histological examinations
1.2.2. Uses advised against
No further relevant information available
Emergency telephone
+49 (0)6132-84463
Icons in SDS
Company Information
company name
Kulzer GmbH
e-mail address of the competent person responsible for the Safety Data Sheet
technik.wehrheim@kulzer-dental.com
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H315, H317, H319, H412
Hazard statements
Code
Statements
H315
Causes skin irritation
Section 2
SECTION 2: Hazards identification
Regulation (EC) No. 1272/2008 Classification of the substance or mixture
Hazard pictograms
GHS07
Hazardous Ingredients
2-hydroxyethyl methacrylate
Hazard statements
H315 Causes skin irritation. H319 Causes serious eye irritation. H317 May cause an allergic skin reaction. H412 Harmful to aquatic life with long lasting effects.
Precautionary statements
P273 Avoid release to the environment. P280 Wear protective gloves/protective clothing/eye protection/face protection. P302+P352 IF ON SKIN: Wash with plenty of soap and water. P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P333+P313 If skin irritation or rash occurs: Get medical advice/attention. P337+P313 If eye irritation persists: Get medical advice/attention.
PBT Substances
Not applicable (Contd. of page 1)
vPvB Substances
Not applicable *
2.1 Classification of the substance or mixture
· Classification according to Regulation (EC) No 1272/2008 Skin Irrit. 2 H315 Causes skin irritation. Eye Irrit. 2 H319 Causes serious eye irritation. Skin Sens. 1 H317 May cause an allergic skin reaction. Aquatic Chronic 3 H412 Harmful to aquatic life with long lasting effects.