General Information
Revision date
2018-05-22
Product name
KRETUS Polyurethane HP, Part B
CAS No.
145899-78-1
Manufacturer Name
Kretus Group 1426 W Collins Ave
Icons in SDS
Company Information
company name
KRETUS GROUP
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H317, H332, H334, H335
Hazard statements
Code
Statements
H317
May cause an allergic skin reaction
Section 2
SECTION 2: Hazards identification
OSHA Emergency Overview: Corrosive. Causes severe burns. Severe respiratory irritant. Severe skin irritant. Severe eye irritant. May cause long-term adverse effects in the aquatic environment.
2.1 Classification of the substance or mixture
Serious Eye Damage Category 1 Skin Sensitization Category 1 Chronic Aquatic Toxicity Category 3
2.2 Label elements
Hazard pictograms/symbols
Signal word
WARNING!
Hazard statements
H317: May cause an allergic skin reaction. H332: Harmful if inhaled. H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled. H335: May cause respiratory irritation.
Precautionary statements
P261: Avoid breathing dust/ fume/ gas/ mist/ vapors/ spray. P273: Avoid release to the environment. P280: Wear protective gloves/ eye protection/ face protection. P305 + P351 + P338 IF IN EYES Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P310: Immediately call a POISON CENTER or doctor/ physician. P333 + P313 If skin irritation or rash occurs Get medical advice/ attention
Potential health effects
Eye contact: Corrosive to the eyes. Severe eye irritation. Skin contact: Corrosive to the skin. Harmful in contact with skin. Potential skin sensitizer. Ingestion: Corrosive and may cause severe and permanent damage to mouth, throat & stomach Inhalation: May cause nose, throat, and lung irritation. Inhalation of vapors and/or aerosols in high concentration may cause irritation of respiratory system. Exposure Guidelines: Target Organs - Respiratory system, Skin, Eyes. Symptoms - Repeated and/or prolonged exposure to low concentrations of vapors and/or aerosols may cause: Sore throat, headache, dizziness, tiredness, nausea and vomiting. General Information: This product contains no listed carcinogens according to IARC, ACGIH, NTP and/or OSHA in concentrations of 0.1 percent or greater. Prolonged contact may result in chemical burns and permanent damage. Repeated or prolonged contact causes sensitization, asthma and eczemas. Read the entire SDS for a more thorough evaluation of the hazards.