Note: Ingredients listed on restricted chemical lists
EC/CAS
80-62-6
Name of the chemical
methacrylic acid, methyl ester
Concentration
N/A
EC/CAS
128-37-0
Name of the chemical
2,6-di-tert-butyl-p-cresol
Concentration
N/A
EC/CAS
107-21-1
Name of the chemical
Ethane-1,2-diol
Concentration
N/A
EC/CAS
150-76-5
Name of the chemical
Mequinol
Concentration
N/A
EC/CAS
204-881-4
Name of the chemical
Butylated Hydroxytoluene
Concentration
N/A
EC/CAS
205-769-8
Name of the chemical
Hydroquinone methylether/Mequinol
Concentration
N/A
General Information
Revision date
2018-02-01
Product name
AT-8040 - Part B
1.2.1 Relevant identified uses
Hardening agent/ Curing agent
1.2.2. Uses advised against
No further relevant information available
Icons in SDS
Company Information
company name
Kömmerling Chemische Fabrik GmbH
e-mail address of the competent person responsible for the Safety Data Sheet
Productsafety@Koe-Chemie.de
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H225, H315, H317, H335, H411
Hazard statements
Code
Statements
H225
Highly Flammable liquid and vapour
Section 2
CLP CLASSIFICATION
Flam. Liq. 2 H225 Highly flammable liquid and vapour. Skin Irrit. 2 H315 Causes skin irritation. Skin Sens. 1 H317 May cause an allergic skin reaction. STOT SE 3 H335 May cause respiratory irritation. Aquatic Chronic 2 H411 Toxic to aquatic life with long lasting effects.
Additional information
The classification resulted from the calculation method of CLP-regulation
2.2 Label elements
Labelling according to Regulation (EC) No 1272/2008 The product is classified and labelled according to the CLP regulation.
Hazard pictograms
GHS02 GHS07 GHS09
Signal word
Danger
Hazardous Ingredients
methyl methacrylate mequinol
Hazard statements
H225 Highly flammable liquid and vapour. H315 Causes skin irritation. H317 May cause an allergic skin reaction. H335 May cause respiratory irritation. H411 Toxic to aquatic life with long lasting effects.
Precautionary statements
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P243 Take action to prevent static discharges. P261 Avoid breathing mist/vapours/spray. P271 Use only outdoors or in a well-ventilated area. P273 Avoid release to the environment. P280 Wear protective gloves / eye protection. P403 Store in a well-ventilated place.
2.3 Other hazards
In the event of a large-scale use of the product, ignition sources in the immediate proximity and in low-lying areas, such as welding equipment, bells, heating elements, refrigerators, storage heaters etc. should be switched off! Erect warning signs warning of the hazardous risk of explosive atmosphere!
PBT Substances
Not applicable
vPvB Substances
Not applicable